title: NVIDIA GPUDirect Remote Direct Memory Access (RDMA)
---

# NVIDIA GPUDirect Remote Direct Memory Access (RDMA) {#rdma-remote-direct-memory-access}

NVIDIA GPUDirect Remote Direct Memory Access (RDMA) allows for an application in one computer to directly access the memory of another computer without needing access through the operating system. This provides the ability to bypass kernel intervention in the process, freeing up resources and greatly reducing the CPU overhead normally needed to process network communications. This is useful for distributing GPU-accelerated workloads across clusters. And because RDMA is so suited toward high bandwidth and low latency applications, this makes it ideal for big data and machine learning applications.

There are currently three configuration methods for NVIDIA GPUDirect RDMA:

Shared device
:   This method allows for an NVIDIA GPUDirect RDMA device to be shared among multiple pods on the OpenShift Container Platform worker node where the device is exposed.

Host device
:   This method provides direct physical Ethernet access on the worker node by creating an additional host network on a pod. A plugin allows the network device to be moved from the host network namespace to the network namespace on the pod.

SR-IOV legacy device
:   The Single Root IO Virtualization (SR-IOV) method can share a single network device, such as an Ethernet adapter, with multiple pods. SR-IOV segments the device, recognized on the host node as a physical function (PF), into multiple virtual functions (VFs).  The VF is used like any other network device.

Each of these methods can be used across either the NVIDIA GPUDirect RDMA over Converged Ethernet (RoCE) or Infiniband infrastructures, providing an aggregate total of six methods of configuration.

## NVIDIA GPUDirect RDMA prerequisites {#rdma-prerequisites_rdma-remote-direct-memory-access}

All methods of NVIDIA GPUDirect RDMA configuration require the installation of specific Operators. Use the following steps to install the Operators:

- Install the [Node Feature Discovery Operator](/openshift-docs-markdown/hardware_enablement/psap-node-feature-discovery-operator#installing-the-node-feature-discovery-operator_node-feature-discovery-operator).
- Install the [SR-IOV Operator](/openshift-docs-markdown/networking/networking_operators/sr-iov-operator/installing-sriov-operator#installing-sriov-operator).
- Install the [NVIDIA Network Operator](https://docs.nvidia.com/networking/display/kubernetes2501/getting-started-openshift.html#network-operator-installation-using-openshift-oc-cli) (NVIDIA documentation).
- Install the [NVIDIA GPU Operator](https://docs.nvidia.com/datacenter/cloud-native/openshift/24.9.2/install-gpu-ocp.html) (NVIDIA documentation).

## Disabling the IRDMA kernel module {#rdma-disabling-irdma-kernel-module_rdma-remote-direct-memory-access}

On some systems, including the DellR750xa, the IRDMA kernel module creates problems for the NVIDIA Network Operator when unloading and loading the DOCA drivers. Use the following procedure to disable the module.

**Procedure**

1. Generate the following machine configuration file by running the following command:

   ```terminal
   $ cat <<EOF > 99-machine-config-blacklist-irdma.yaml
   ```

   ```yaml {title="Example output"}
   apiVersion: machineconfiguration.openshift.io/v1
   kind: MachineConfig
   metadata:
     labels:
       machineconfiguration.openshift.io/role: worker
     name: 99-worker-blacklist-irdma
   spec:
     kernelArguments:
       - "module_blacklist=irdma"
   ```
2. Create the machine configuration on the cluster and wait for the nodes to reboot by running the following command:

   ```terminal
   $ oc create -f 99-machine-config-blacklist-irdma.yaml
   ```

   ```terminal {title="Example output"}
   machineconfig.machineconfiguration.openshift.io/99-worker-blacklist-irdma created
   ```
3. Validate in a debug pod on each node that the module has not loaded by running the following command:

   ```terminal
   $ oc debug node/nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
   Starting pod/nvd-srv-32nvidiaengrdu2dcredhatcom-debug-btfj2 ...
   To use host binaries, run `chroot /host`
   Pod IP: 10.6.135.11
   If you don't see a command prompt, try pressing enter.
   sh-5.1# chroot /host
   sh-5.1# lsmod|grep irdma
   sh-5.1#
   ```

## Creating persistent naming rules {#rdma-creating-persistent-naming-rules_rdma-remote-direct-memory-access}

In some cases, device names won’t persist following a reboot. For example, on R760xa systems Mellanox devices might be renamed after a reboot. You can avoid this problem by using a `MachineConfig` to set persistence.

**Procedure**

1. Gather the MAC address names from the worker nodes for the node into a file and provide names for the interfaces that need to persist. This example uses the file `70-persistent-net.rules` and stashes the details in it.

   ```terminal
   $ cat <<EOF > 70-persistent-net.rules
   SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:3b:51:28",ATTR{type}=="1",NAME="ibs2f0"
   SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:3b:51:29",ATTR{type}=="1",NAME="ens8f0np0"
   SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:f0:36:d0",ATTR{type}=="1",NAME="ibs2f0"
   SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:f0:36:d1",ATTR{type}=="1",NAME="ens8f0np0"
   EOF
   ```
2. Convert that file into a base64 string without line breaks and set the output to the variable `PERSIST`:

   ```terminal
   $ PERSIST=`cat 70-persistent-net.rules| base64 -w 0`
   ```

   ```terminal
   $ echo $PERSIST
   ```

   ```terminal
   U1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjozYjo1MToyOCIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImliczJmMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjozYjo1MToyOSIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImVuczhmMG5wMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjpmMDozNjpkMCIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImliczJmMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjpmMDozNjpkMSIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImVuczhmMG5wMCIK
   ```
3. Create a machine configuration and set the base64 encoding in the custom resource file by running the following command:

   ```terminal
   $ cat <<EOF > 99-machine-config-udev-network.yaml
   ```

   ```yaml
   apiVersion: machineconfiguration.openshift.io/v1
   kind: MachineConfig
   metadata:
      labels:
        machineconfiguration.openshift.io/role: worker
      name: 99-machine-config-udev-network
   spec:
      config:
        ignition:
          version: 3.2.0
        storage:
          files:
          - contents:
              source: data:text/plain;base64,$PERSIST
            filesystem: root
            mode: 420
            path: /etc/udev/rules.d/70-persistent-net.rules
   ```
4. Create the machine configuration on the cluster by running the following command. After running the command, the expected output shows `machineconfig.machineconfiguration.openshift.io/99-machine-config-udev-network created`.

   ```terminal
   $ oc create -f 99-machine-config-udev-network.yaml
   ```
5. Use the `get mcp` command to view the machine configuration status:

   ```terminal
   $ oc get mcp
   ```

   ```terminal {title="Example output"}
   NAME     CONFIG                                             UPDATED   UPDATING   DEGRADED   MACHINECOUNT   READYMACHINECOUNT   UPDATEDMACHINECOUNT   DEGRADEDMACHINECOUNT   AGE
   master   rendered-master-9adfe851c2c14d9598eea5ec3df6c187   True      False      False      1              1                   1                     0                      6h21m
   worker   rendered-worker-4568f1b174066b4b1a4de794cf538fee   False     True       False      2              0                   0                     0                      6h21m
   ```

The nodes will reboot and when the updating field returns to `false`, you can validate on the nodes by looking at the devices in a debug pod.

## Configuring the NFD Operator {#rdma-configuring-the-nfd-operator_rdma-remote-direct-memory-access}

The Node Feature Discovery (NFD) Operator manages the detection of hardware features and configuration in an OpenShift Container Platform cluster by labeling the nodes with hardware-specific information. NFD labels the host with node-specific attributes, such as PCI cards, kernel, operating system version, and so on.

**Prerequisites**

- You have installed the NFD Operator.

.Procedure 1.  Validate that the Operator is installed and running by looking at the pods in the `openshift-nfd` namespace by running the following command: `terminal         $ oc get pods -n openshift-nfd         ` `terminal title="Example output"         NAME                                      READY   STATUS    RESTARTS   AGE         nfd-controller-manager-8698c88cdd-t8gbc   2/2     Running   0          2m         ` 1.  With the NFD controller running, generate the `NodeFeatureDiscovery` instance and add it to the cluster.

````
    The `ClusterServiceVersion` specification for NFD Operator provides default values, including the NFD operand image that is part of the Operator payload. Retrieve its value by running the following command:
    ```terminal
    $ NFD_OPERAND_IMAGE=`echo $(oc get csv -n openshift-nfd -o json | jq -r '.items[0].metadata.annotations["alm-examples"]') | jq -r '.[] | select(.kind == "NodeFeatureDiscovery") | .spec.operand.image'`
    ```
1.  Optional: Add entries to the default `deviceClassWhiteList` field, to support more network adapters, such as the NVIDIA BlueField DPUs.
    ```terminal
    apiVersion: nfd.openshift.io/v1
    kind: NodeFeatureDiscovery
    metadata:
      name: nfd-instance
      namespace: openshift-nfd
    spec:
      instance: ''
      operand:
        image: '${NFD_OPERAND_IMAGE}'
        servicePort: 12000
      prunerOnDelete: false
      topologyUpdater: false
      workerConfig:
        configData: |
          core:
            sleepInterval: 60s
          sources:
            pci:
              deviceClassWhitelist:
                - "02"
                - "03"
                - "0200"
                - "0207"
                - "12"
              deviceLabelFields:
                - "vendor"
    ```
1.  Create the 'NodeFeatureDiscovery` instance by running the following command:
    ```terminal
    $ oc create -f nfd-instance.yaml
    ```
    ```terminal title="Example output"
    nodefeaturediscovery.nfd.openshift.io/nfd-instance created
    ```
1.  Validate that the instance is up and running by looking at the pods under the `openshift-nfd` namespace by running the following command:
    ```terminal
    $ oc get pods -n openshift-nfd
    ```
    ```terminal title="Example output"
    NAME                                    READY   STATUS    RESTARTS   AGE
    nfd-controller-manager-7cb6d656-jcnqb   2/2     Running   0          4m
    nfd-gc-7576d64889-s28k9                 1/1     Running   0          21s
    nfd-master-b7bcf5cfd-qnrmz              1/1     Running   0          21s
    nfd-worker-96pfh                        1/1     Running   0          21s
    nfd-worker-b2gkg                        1/1     Running   0          21s
    nfd-worker-bd9bk                        1/1     Running   0          21s
    nfd-worker-cswf4                        1/1     Running   0          21s
    nfd-worker-kp6gg                        1/1     Running   0          21s
    ```
1.  Wait a short period of time and then verify that NFD has added labels to the node. The NFD labels are prefixed with `feature.node.kubernetes.io`, so you can easily filter them.
    ```terminal
    $ oc get node -o json | jq '.items[0].metadata.labels | with_entries(select(.key | startswith("feature.node.kubernetes.io")))'
    {
      "feature.node.kubernetes.io/cpu-cpuid.ADX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AESNI": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AVX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AVX2": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CETSS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CLZERO": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CMPXCHG8": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CPBOOST": "true",
      "feature.node.kubernetes.io/cpu-cpuid.EFER_LMSLE_UNS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FMA3": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FP256": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FSRM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FXSR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FXSROPT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBPB": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS_PREFERRED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS_PROVIDES_SMP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSBRNTRGT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSFETCHSAM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSFFV": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPCNT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPCNTEXT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPSAM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSRDWROPCNT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSRIPINVALIDCHK": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_FETCH_CTLX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_OPFUSE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_PREVENTHOST": "true",
      "feature.node.kubernetes.io/cpu-cpuid.INT_WBINVD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.INVLPGB": "true",
      "feature.node.kubernetes.io/cpu-cpuid.LAHF": "true",
      "feature.node.kubernetes.io/cpu-cpuid.LBRVIRT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MCAOVERFLOW": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MCOMMIT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MOVBE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MOVU": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MSRIRC": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MSR_PAGEFLUSH": "true",
      "feature.node.kubernetes.io/cpu-cpuid.NRIPS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.OSXSAVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.PPIN": "true",
      "feature.node.kubernetes.io/cpu-cpuid.PSFD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.RDPRU": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_64BIT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_ALTERNATIVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_DEBUGSWAP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_ES": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_RESTRICTED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_SNP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SHA": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SME": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SME_COHERENT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SPEC_CTRL_SSBD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SSE4A": "true",
      "feature.node.kubernetes.io/cpu-cpuid.STIBP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.STIBP_ALWAYSON": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SUCCOR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMDA": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMFBASID": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVML": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMNP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMPF": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMPFT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SYSCALL": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SYSEE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TLB_FLUSH_NESTED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TOPEXT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TSCRATEMSR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VAES": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMCBCLEAN": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMPL": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMSA_REGPROT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VPCLMULQDQ": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VTE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.WBNOINVD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.X87": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XGETBV1": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVEC": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVEOPT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVES": "true",
      "feature.node.kubernetes.io/cpu-hardware_multithreading": "false",
      "feature.node.kubernetes.io/cpu-model.family": "25",
      "feature.node.kubernetes.io/cpu-model.id": "1",
      "feature.node.kubernetes.io/cpu-model.vendor_id": "AMD",
      "feature.node.kubernetes.io/kernel-config.NO_HZ": "true",
      "feature.node.kubernetes.io/kernel-config.NO_HZ_FULL": "true",
      "feature.node.kubernetes.io/kernel-selinux.enabled": "true",
      "feature.node.kubernetes.io/kernel-version.full": "5.14.0-427.35.1.el9_4.x86_64",
      "feature.node.kubernetes.io/kernel-version.major": "5",
      "feature.node.kubernetes.io/kernel-version.minor": "14",
      "feature.node.kubernetes.io/kernel-version.revision": "0",
      "feature.node.kubernetes.io/memory-numa": "true",
      "feature.node.kubernetes.io/network-sriov.capable": "true",
      "feature.node.kubernetes.io/pci-102b.present": "true",
      "feature.node.kubernetes.io/pci-10de.present": "true",
      "feature.node.kubernetes.io/pci-10de.sriov.capable": "true",
      "feature.node.kubernetes.io/pci-15b3.present": "true",
      "feature.node.kubernetes.io/pci-15b3.sriov.capable": "true",
      "feature.node.kubernetes.io/rdma.available": "true",
      "feature.node.kubernetes.io/rdma.capable": "true",
      "feature.node.kubernetes.io/storage-nonrotationaldisk": "true",
      "feature.node.kubernetes.io/system-os_release.ID": "rhcos",
      "feature.node.kubernetes.io/system-os_release.OPENSHIFT_VERSION": "4.17",
      "feature.node.kubernetes.io/system-os_release.OSTREE_VERSION": "417.94.202409121747-0",
      "feature.node.kubernetes.io/system-os_release.RHEL_VERSION": "9.4",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID": "4.17",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID.major": "4",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID.minor": "17"
    }
    ```
1.  Confirm there is a network device that is discovered:
    ```terminal
    $ oc describe node | grep -E 'Roles|pci' | grep pci-15b3
                        feature.node.kubernetes.io/pci-15b3.present=true
                        feature.node.kubernetes.io/pci-15b3.sriov.capable=true
                        feature.node.kubernetes.io/pci-15b3.present=true
                        feature.node.kubernetes.io/pci-15b3.sriov.capable=true
    ```
````

## Configuring the SR-IOV Operator {#rdma-configuring-the-sriov-operator_rdma-remote-direct-memory-access}

Single root I/O virtualization (SR-IOV) enhances the performance of NVIDIA GPUDirect RDMA by providing sharing across multiple pods from a single device.

**Prerequisites**

- You have installed the SR-IOV Operator.

**Procedure**

1. Validate that the Operator is installed and running by looking at the pods in the `openshift-sriov-network-operator` namespace by running the following command:

   ```terminal
   $ oc get pods -n openshift-sriov-network-operator
   ```

   ```terminal {title="Example output"}
   NAME                                      READY   STATUS    RESTARTS   AGE
   sriov-network-operator-7cb6c49868-89486   1/1     Running   0          22s
   ```
2. For the default `SriovOperatorConfig` CR to work with the MLNX_OFED container, run this command to update the following values:

   ```yaml
   apiVersion: sriovnetwork.openshift.io/v1
   kind: SriovOperatorConfig
   metadata:
     name: default
     namespace: openshift-sriov-network-operator
   spec:
     enableInjector: true
     enableOperatorWebhook: true
     logLevel: 2
   ```
3. Create the resource on the cluster by running the following command:

   ```terminal
   $ oc create -f sriov-operator-config.yaml
   ```

   ```terminal {title="Example output"}
   sriovoperatorconfig.sriovnetwork.openshift.io/default created
   ```
4. Patch the sriov-operator so the MOFED container can work with it by running the following command:

   ```terminal
   $ oc patch sriovoperatorconfig default   --type=merge -n openshift-sriov-network-operator   --patch '{ "spec": { "configDaemonNodeSelector": { "network.nvidia.com/operator.mofed.wait": "false", "node-role.kubernetes.io/worker": "", "feature.node.kubernetes.io/pci-15b3.sriov.capable": "true" } } }'
   ```

   ```terminal {title="Example output"}
   sriovoperatorconfig.sriovnetwork.openshift.io/default patched
   ```

## Configuring the NVIDIA network Operator {#rdma-configuring-the-nvidia-network-operator_rdma-remote-direct-memory-access}

The NVIDIA network Operator manages NVIDIA networking resources and networking related components such as drivers and device plugins to enable NVIDIA GPUDirect RDMA workloads.

**Prerequisites**

- You have installed the NVIDIA network Operator.

**Procedure**

1. Validate that the network Operator is installed and running by confirming the controller is running in the `nvidia-network-operator` namespace by running the following command:

   ```terminal
   $ oc get pods -n nvidia-network-operator
   ```

   ```terminal {title="Example output"}
   NAME                                                          READY   STATUS             RESTARTS        AGE
   nvidia-network-operator-controller-manager-6f7d6956cd-fw5wg   1/1     Running            0                5m
   ```
2. With the Operator running, create the `NicClusterPolicy` custom resource file. The device you choose depends on your system configuration. In this example, the Infiniband interface `ibs2f0` is hard coded and is used as the shared NVIDIA GPUDirect RDMA device.

   ```yaml
   apiVersion: mellanox.com/v1alpha1
   kind: NicClusterPolicy
   metadata:
     name: nic-cluster-policy
   spec:
     nicFeatureDiscovery:
       image: nic-feature-discovery
       repository: ghcr.io/mellanox
       version: v0.0.1
     docaTelemetryService:
       image: doca_telemetry
       repository: nvcr.io/nvidia/doca
       version: 1.16.5-doca2.6.0-host
     rdmaSharedDevicePlugin:
       config: |
         {
           "configList": [
             {
               "resourceName": "rdma_shared_device_ib",
               "rdmaHcaMax": 63,
               "selectors": {
                 "ifNames": ["ibs2f0"]
               }
             },
             {
               "resourceName": "rdma_shared_device_eth",
               "rdmaHcaMax": 63,
               "selectors": {
                 "ifNames": ["ens8f0np0"]
               }
             }
           ]
         }
       image: k8s-rdma-shared-dev-plugin
       repository: ghcr.io/mellanox
       version: v1.5.1
     secondaryNetwork:
       ipoib:
         image: ipoib-cni
         repository: ghcr.io/mellanox
         version: v1.2.0
     nvIpam:
       enableWebhook: false
       image: nvidia-k8s-ipam
       repository: ghcr.io/mellanox
       version: v0.2.0
     ofedDriver:
       readinessProbe:
         initialDelaySeconds: 10
         periodSeconds: 30
       forcePrecompiled: false
       terminationGracePeriodSeconds: 300
       livenessProbe:
         initialDelaySeconds: 30
         periodSeconds: 30
       upgradePolicy:
         autoUpgrade: true
         drain:
           deleteEmptyDir: true
           enable: true
           force: true
           timeoutSeconds: 300
           podSelector: ''
         maxParallelUpgrades: 1
         safeLoad: false
         waitForCompletion:
           timeoutSeconds: 0
       startupProbe:
         initialDelaySeconds: 10
         periodSeconds: 20
       image: doca-driver
       repository: nvcr.io/nvidia/mellanox
       version: 24.10-0.7.0.0-0
       env:
       - name: UNLOAD_STORAGE_MODULES
         value: "true"
       - name: RESTORE_DRIVER_ON_POD_TERMINATION
         value: "true"
       - name: CREATE_IFNAMES_UDEV
         value: "true"
   ```
3. Create the `NicClusterPolicy` custom resource on the cluster by running the following command:

   ```terminal
   $ oc create -f network-sharedrdma-nic-cluster-policy.yaml
   ```

   ```terminal {title="Example output"}
   nicclusterpolicy.mellanox.com/nic-cluster-policy created
   ```
4. Validate the `NicClusterPolicy` by running the following command in the DOCA/MOFED container:

   ```terminal
   $ oc get pods -n nvidia-network-operator
   ```

   ```terminal {title="Example output"}
   NAME                                                          READY   STATUS    RESTARTS   AGE
   doca-telemetry-service-hwj65                                  1/1     Running   2          160m
   kube-ipoib-cni-ds-fsn8g                                       1/1     Running   2          160m
   mofed-rhcos4.16-9b5ddf4c6-ds-ct2h5                            2/2     Running   4          160m
   nic-feature-discovery-ds-dtksz                                1/1     Running   2          160m
   nv-ipam-controller-854585f594-c5jpp                           1/1     Running   2          160m
   nv-ipam-controller-854585f594-xrnp5                           1/1     Running   2          160m
   nv-ipam-node-xqttl                                            1/1     Running   2          160m
   nvidia-network-operator-controller-manager-5798b564cd-5cq99   1/1     Running   2         5d23h
   rdma-shared-dp-ds-p9vvg                                       1/1     Running   0          85m
   ```
5. `rsh` into the `mofed` container to check the status by running the following command:

   ```terminal
   $ MOFED_POD=$(oc get pods -n nvidia-network-operator -o name | grep mofed)
   $ oc rsh -n nvidia-network-operator -c mofed-container ${MOFED_POD}
   sh-5.1# ofed_info -s
   ```

   ```terminal {title="Example output"}
   OFED-internal-24.07-0.6.1:
   ```

   ```terminal
   sh-5.1# ibdev2netdev -v
   ```

   ```terminal {title="Example output"}
   0000:0d:00.0 mlx5_0 (MT41692 - 900-9D3B4-00EN-EA0) BlueField-3 E-series SuperNIC 400GbE/NDR single port QSFP112, PCIe Gen5.0 x16 FHHL, Crypto Enabled, 16GB DDR5, BMC, Tall Bracket                                                       fw 32.42.1000 port 1 (ACTIVE) ==> ibs2f0 (Up)
   0000:a0:00.0 mlx5_1 (MT41692 - 900-9D3B4-00EN-EA0) BlueField-3 E-series SuperNIC 400GbE/NDR single port QSFP112, PCIe Gen5.0 x16 FHHL, Crypto Enabled, 16GB DDR5, BMC, Tall Bracket                                                       fw 32.42.1000 port 1 (ACTIVE) ==> ens8f0np0 (Up)
   ```
6. Create a `IPoIBNetwork` custom resource file:

   ```yaml
   apiVersion: mellanox.com/v1alpha1
   kind: IPoIBNetwork
   metadata:
     name: example-ipoibnetwork
   spec:
     ipam: |
       {
         "type": "whereabouts",
         "range": "192.168.6.225/28",
         "exclude": [
          "192.168.6.229/30",
          "192.168.6.236/32"
         ]
       }
     master: ibs2f0
     networkNamespace: default
   ```
7. Create the `IPoIBNetwork` resource on the cluster by running the following command:

   ```terminal
   $ oc create -f ipoib-network.yaml
   ```

   ```terminal {title="Example output"}
   ipoibnetwork.mellanox.com/example-ipoibnetwork created
   ```
8. Create a `MacvlanNetwork` custom resource file for your other interface:

   ```yaml
   apiVersion: mellanox.com/v1alpha1
   kind: MacvlanNetwork
   metadata:
     name: rdmashared-net
   spec:
     networkNamespace: default
     master: ens8f0np0
     mode: bridge
     mtu: 1500
     ipam: '{"type": "whereabouts", "range": "192.168.2.0/24", "gateway": "192.168.2.1"}'
   ```
9. Create the resource on the cluster by running the following command:

   ```terminal
   $ oc create -f macvlan-network.yaml
   ```

   ```terminal {title="Example output"}
   macvlannetwork.mellanox.com/rdmashared-net created
   ```

## Configuring the GPU Operator {#rdma-configuring-the-gpu-operator_rdma-remote-direct-memory-access}

The GPU Operator automates the management of the NVIDIA drivers, device plugins for GPUs, the NVIDIA Container Toolkit, and other components required for GPU provisioning.

**Prerequisites**

- You have installed the GPU Operator.

**Procedure**

1. Check that the Operator pod is running to look at the pods under the namespace by running the following command:

   ```terminal
   $ oc get pods -n nvidia-gpu-operator
   ```

   ```terminal {title="Example output"}
   NAME                          READY   STATUS    RESTARTS   AGE
   gpu-operator-b4cb7d74-zxpwq   1/1     Running   0          32s
   ```
2. Create a GPU cluster policy custom resource file similar to the following example:

   ```yaml
   apiVersion: nvidia.com/v1
   kind: ClusterPolicy
   metadata:
     name: gpu-cluster-policy
   spec:
     vgpuDeviceManager:
       enabled: true
     migManager:
       config:
         default: all-disabled
         name: default-mig-parted-config
       enabled: true
     operator:
       defaultRuntime: crio
       initContainer: {}
       runtimeClass: nvidia
       use_ocp_driver_toolkit: true
     dcgm:
       enabled: true
     gfd:
       enabled: true
     dcgmExporter:
       config:
         name: ''
       serviceMonitor:
         enabled: true
       enabled: true
     cdi:
       default: false
       enabled: false
     driver:
       licensingConfig:
         nlsEnabled: true
         configMapName: ''
       certConfig:
         name: ''
       rdma:
         enabled: false
       kernelModuleConfig:
         name: ''
       upgradePolicy:
         autoUpgrade: true
         drain:
           deleteEmptyDir: false
           enable: false
           force: false
           timeoutSeconds: 300
         maxParallelUpgrades: 1
         maxUnavailable: 25%
         podDeletion:
           deleteEmptyDir: false
           force: false
           timeoutSeconds: 300
         waitForCompletion:
           timeoutSeconds: 0
       repoConfig:
         configMapName: ''
       virtualTopology:
         config: ''
       enabled: true
       useNvidiaDriverCRD: false
       useOpenKernelModules: true
     devicePlugin:
       config:
         name: ''
         default: ''
       mps:
         root: /run/nvidia/mps
       enabled: true
     gdrcopy:
       enabled: true
     kataManager:
       config:
         artifactsDir: /opt/nvidia-gpu-operator/artifacts/runtimeclasses
     mig:
       strategy: single
     sandboxDevicePlugin:
       enabled: true
     validator:
       plugin:
         env:
           - name: WITH_WORKLOAD
             value: 'false'
     nodeStatusExporter:
       enabled: true
     daemonsets:
       rollingUpdate:
         maxUnavailable: '1'
       updateStrategy: RollingUpdate
     sandboxWorkloads:
       defaultWorkload: container
       enabled: false
     gds:
       enabled: true
       image: nvidia-fs
       version: 2.20.5
       repository: nvcr.io/nvidia/cloud-native
     vgpuManager:
       enabled: false
     vfioManager:
       enabled: true
     toolkit:
       installDir: /usr/local/nvidia
       enabled: true
   ```
3. When the GPU `ClusterPolicy` custom resource has generated, create the resource on the cluster by running the following command:

   ```terminal
   $ oc create -f gpu-cluster-policy.yaml
   ```

   ```terminal {title="Example output"}
   clusterpolicy.nvidia.com/gpu-cluster-policy created
   ```
4. Validate that the Operator is installed and running by running the following command:

   ```terminal
   $ oc get pods -n nvidia-gpu-operator
   ```

   ```terminal {title="Example output"}
   NAME                                                  READY   STATUS      RESTARTS   AGE
   gpu-feature-discovery-d5ngn                           1/1     Running     0          3m20s
   gpu-feature-discovery-z42rx                           1/1     Running     0          3m23s
   gpu-operator-6bb4d4b4c5-njh78                         1/1     Running     0          4m35s
   nvidia-container-toolkit-daemonset-bkh8l              1/1     Running     0          3m20s
   nvidia-container-toolkit-daemonset-c4hzm              1/1     Running     0          3m23s
   nvidia-cuda-validator-4blvg                           0/1     Completed   0          106s
   nvidia-cuda-validator-tw8sl                           0/1     Completed   0          112s
   nvidia-dcgm-exporter-rrw4g                            1/1     Running     0          3m20s
   nvidia-dcgm-exporter-xc78t                            1/1     Running     0          3m23s
   nvidia-dcgm-nvxpf                                     1/1     Running     0          3m20s
   nvidia-dcgm-snj4j                                     1/1     Running     0          3m23s
   nvidia-device-plugin-daemonset-fk2xz                  1/1     Running     0          3m23s
   nvidia-device-plugin-daemonset-wq87j                  1/1     Running     0          3m20s
   nvidia-driver-daemonset-416.94.202410211619-0-ngrjg   4/4     Running     0          3m58s
   nvidia-driver-daemonset-416.94.202410211619-0-tm4x6   4/4     Running     0          3m58s
   nvidia-node-status-exporter-jlzxh                     1/1     Running     0          3m57s
   nvidia-node-status-exporter-zjffs                     1/1     Running     0          3m57s
   nvidia-operator-validator-l49hx                       1/1     Running     0          3m20s
   nvidia-operator-validator-n44nn                       1/1     Running     0          3m23s
   ```
5. Optional: When you have verified the pods are running, remote shell into the NVIDIA driver daemonset pod and confirm that the NVIDIA modules are loaded. Specifically, ensure the `nvidia_peermem` is loaded.

   ```terminal
   $ oc rsh -n nvidia-gpu-operator $(oc -n nvidia-gpu-operator get pod -o name -l app.kubernetes.io/component=nvidia-driver)
   sh-4.4# lsmod|grep nvidia
   ```

   ```terminal {title="Example output"}
   nvidia_fs             327680  0
   nvidia_peermem         24576  0
   nvidia_modeset       1507328  0
   video                  73728  1 nvidia_modeset
   nvidia_uvm           6889472  8
   nvidia               8810496  43 nvidia_uvm,nvidia_peermem,nvidia_fs,gdrdrv,nvidia_modeset
   ib_uverbs             217088  3 nvidia_peermem,rdma_ucm,mlx5_ib
   drm                   741376  5 drm_kms_helper,drm_shmem_helper,nvidia,mgag200
   ```
6. Optional: Run the `nvidia-smi` utility to show the details about the driver and the hardware:

```terminal
sh-4.4# nvidia-smi
```

````
```terminal title="Example output"
Wed Nov  6 22:03:53 2024
+-----------------------------------------------------------------------------------------+
| NVIDIA-SMI 550.90.07              Driver Version: 550.90.07      CUDA Version: 12.4     |
|-----------------------------------------+------------------------+----------------------+
| GPU  Name                 Persistence-M | Bus-Id          Disp.A | Volatile Uncorr. ECC |
| Fan  Temp   Perf          Pwr:Usage/Cap |           Memory-Usage | GPU-Util  Compute M. |
|                                         |                        |               MIG M. |
|=========================================+========================+======================|
|   0  NVIDIA A40                     On  |   00000000:61:00.0 Off |                    0 |
|  0%   37C    P0             88W /  300W |       1MiB /  46068MiB |      0%      Default |
|                                         |                        |                  N/A |
+-----------------------------------------+------------------------+----------------------+
|   1  NVIDIA A40                     On  |   00000000:E1:00.0 Off |                    0 |
|  0%   28C    P8             29W /  300W |       1MiB /  46068MiB |      0%      Default |
|                                         |                        |                  N/A |
+-----------------------------------------+------------------------+----------------------+

+-----------------------------------------------------------------------------------------+
| Processes:                                                                              |
|  GPU   GI   CI        PID   Type   Process name                              GPU Memory |
|        ID   ID                                                               Usage      |
|=========================================================================================|
|  No running processes found                                                             |
+-----------------------------------------------------------------------------------------+
```
````

1. While you are still in the driver pod, set the GPU clock to maximum using the `nvidia-smi` command:

   ```terminal
   $ oc rsh -n nvidia-gpu-operator nvidia-driver-daemonset-416.94.202410172137-0-ndhzc
   sh-4.4# nvidia-smi -i 0 -lgc $(nvidia-smi -i 0 --query-supported-clocks=graphics --format=csv,noheader,nounits | sort -h | tail -n 1)
   ```

   ```terminal {title="Example output"}
   GPU clocks set to "(gpuClkMin 1740, gpuClkMax 1740)" for GPU 00000000:61:00.0
   All done.
   ```

   ```terminal
   sh-4.4# nvidia-smi -i 1 -lgc $(nvidia-smi -i 1 --query-supported-clocks=graphics --format=csv,noheader,nounits | sort -h | tail -n 1)
   ```

   ```terminal {title="Example output"}
   GPU clocks set to "(gpuClkMin 1740, gpuClkMax 1740)" for GPU 00000000:E1:00.0
   All done.
   ```
2. Validate the resource is available from a node describe perspective by running the following command:

   ```terminal
   $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A9
   ```

   ```terminal {title="Example output"}
   Capacity:
     cpu:                          128
     ephemeral-storage:            1561525616Ki
     hugepages-1Gi:                0
     hugepages-2Mi:                0
     memory:                       263596712Ki
     nvidia.com/gpu:               2
     pods:                         250
     rdma/rdma_shared_device_eth:  63
     rdma/rdma_shared_device_ib:   63
   Allocatable:
     cpu:                          127500m
     ephemeral-storage:            1438028263499
     hugepages-1Gi:                0
     hugepages-2Mi:                0
     memory:                       262445736Ki
     nvidia.com/gpu:               2
     pods:                         250
     rdma/rdma_shared_device_eth:  63
     rdma/rdma_shared_device_ib:   63
   --
   Capacity:
     cpu:                          128
     ephemeral-storage:            1561525616Ki
     hugepages-1Gi:                0
     hugepages-2Mi:                0
     memory:                       263596672Ki
     nvidia.com/gpu:               2
     pods:                         250
     rdma/rdma_shared_device_eth:  63
     rdma/rdma_shared_device_ib:   63
   Allocatable:
     cpu:                          127500m
     ephemeral-storage:            1438028263499
     hugepages-1Gi:                0
     hugepages-2Mi:                0
     memory:                       262445696Ki
     nvidia.com/gpu:               2
     pods:                         250
     rdma/rdma_shared_device_eth:  63
     rdma/rdma_shared_device_ib:   63
   ```

## Creating the machine configuration {#rdma-creating-the-machine-configuration_rdma-remote-direct-memory-access}

Before you create the resource pods, you need to create the `machineconfig.yaml` custom resource (CR) that provides access to the GPU and networking resources without the need for user privileges.

**Procedure**

1. Generate a `Machineconfig` CR:

   ```yaml
   apiVersion: machineconfiguration.openshift.io/v1
   kind: MachineConfig
   metadata:
     labels:
       machineconfiguration.openshift.io/role: worker
     name: 02-worker-container-runtime
   spec:
     config:
       ignition:
         version: 3.2.0
       storage:
         files:
         - contents:
             source: data:text/plain;charset=utf-8;base64,W2NyaW8ucnVudGltZV0KZGVmYXVsdF91bGltaXRzID0gWwoibWVtbG9jaz0tMTotMSIKXQo=
           mode: 420
           overwrite: true
           path: /etc/crio/crio.conf.d/10-custom
   ```

## Creating the workload pods {#rdma-creating-workload-pods_rdma-remote-direct-memory-access}

Use the procedures in this section to create the workload pods for the shared and host devices.

### Creating a shared device RDMA on RoCE {#rdma-creating-shared-device-rdma-roce_rdma-remote-direct-memory-access}

Create the workload pods for a shared device RDMA on RDMA over Converged Ethernet (RoCE) for the NVIDIA Network Operator and test the pod configuration.

The NVIDIA GPUDirect RDMA device is shared among pods on the OpenShift Container Platform worker node where the device is exposed.

**Prerequisites**

- Ensure that the Operator is running.
- Delete the `NicClusterPolicy` custom resource (CR), if it exists.

**Procedure**

1. Generate custom pod resources:

   ```yaml
   $ cat <<EOF > rdma-eth-32-workload.yaml
   apiVersion: v1
   kind: Pod
   metadata:
     name: rdma-eth-32-workload
     namespace: default
     annotations:
       k8s.v1.cni.cncf.io/networks: rdmashared-net
   spec:
     nodeSelector:
       kubernetes.io/hostname: nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
     containers:
     - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
       name: rdma-eth-32-workload
       resources:
         limits:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_eth: 1
         requests:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_eth: 1

   EOF

   $ cat <<EOF > rdma-eth-33-workload.yaml
   apiVersion: v1
   kind: Pod
   metadata:
     name: rdma-eth-33-workload
     namespace: default
     annotations:
       k8s.v1.cni.cncf.io/networks: rdmashared-net
   spec:
     nodeSelector:
       kubernetes.io/hostname: nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
     containers:
     - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
       name: rdma-eth-33-workload
       securityContext:
         capabilities:
           add: [ "IPC_LOCK" ]
       resources:
         limits:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_eth: 1
         requests:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_eth: 1
   EOF
   ```
2. Create the pods on the cluster by using the following commands:

   ```terminal
   $ oc create -f rdma-eth-32-workload.yaml
   ```

   ```terminal {title="Example output"}
   pod/rdma-eth-32-workload created
   ```

   ```terminal
   $ oc create -f rdma-eth-33-workload.yaml
   ```

   ```terminal {title="Example output"}
   pod/rdma-eth-33-workload created
   ```
3. Verify that the pods are running by using the following command:

   ```terminal
   $ oc get pods -n default
   ```

   ```terminal {title="Example output"}
   NAME                   READY   STATUS    RESTARTS   AGE
   rdma-eth-32-workload   1/1     Running   0          25s
   rdma-eth-33-workload   1/1     Running   0          22s
   ```

### Creating a host device RDMA on RoCE {#rdma-creating-host-device-rdma-roce_rdma-remote-direct-memory-access}

Create the workload pods for a host device Remote Direct Memory Access (RDMA) for the NVIDIA Network Operator and test the pod configuration.

**Prerequisites**

- Ensure that the Operator is running.
- Delete the `NicClusterPolicy` custom resource (CR), if it exists.

**Procedure**

1. Generate a new host device `NicClusterPolicy` (CR), as shown below:

   ```yaml
   $ cat <<EOF > network-hostdev-nic-cluster-policy.yaml
   apiVersion: mellanox.com/v1alpha1
   kind: NicClusterPolicy
   metadata:
     name: nic-cluster-policy
   spec:
     ofedDriver:
       image: doca-driver
       repository: nvcr.io/nvidia/mellanox
       version: 24.10-0.7.0.0-0
       startupProbe:
         initialDelaySeconds: 10
         periodSeconds: 20
       livenessProbe:
         initialDelaySeconds: 30
         periodSeconds: 30
       readinessProbe:
         initialDelaySeconds: 10
         periodSeconds: 30
       env:
       - name: UNLOAD_STORAGE_MODULES
         value: "true"
       - name: RESTORE_DRIVER_ON_POD_TERMINATION
         value: "true"
       - name: CREATE_IFNAMES_UDEV
         value: "true"
     sriovDevicePlugin:
         image: sriov-network-device-plugin
         repository: ghcr.io/k8snetworkplumbingwg
         version: v3.7.0
         config: |
           {
             "resourceList": [
                 {
                     "resourcePrefix": "nvidia.com",
                     "resourceName": "hostdev",
                     "selectors": {
                         "vendors": ["15b3"],
                         "isRdma": true
                     }
                 }
             ]
           }
   EOF
   ```
2. Create the `NicClusterPolicy` CR on the cluster by using the following command:

   ```terminal
   $ oc create -f network-hostdev-nic-cluster-policy.yaml
   ```

   ```terminal {title="Example output"}
   nicclusterpolicy.mellanox.com/nic-cluster-policy created
   ```
3. Verify that the host device `NicClusterPolicy` CR by using the following command in the DOCA/MOFED container:

   ```terminal
   $ oc get pods -n nvidia-network-operator
   ```

   ```terminal {title="Example output"}
   NAME                                                          READY   STATUS    RESTARTS   AGE
   mofed-rhcos4.16-696886fcb4-ds-9sgvd                           2/2     Running   0          2m37s
   mofed-rhcos4.16-696886fcb4-ds-lkjd4                           2/2     Running   0          2m37s
   nvidia-network-operator-controller-manager-68d547dbbd-qsdkf   1/1     Running   0          141m
   sriov-device-plugin-6v2nz                                     1/1     Running   0          2m14s
   sriov-device-plugin-hc4t8                                     1/1     Running   0          2m14s
   ```
4. Confirm that the resources appear in the cluster `oc describe node` section by using the following command:

   ```terminal
   $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A7
   ```

   ```terminal {title="Example output"}
   Capacity:
     cpu:                 128
     ephemeral-storage:   1561525616Ki
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              263596708Ki
     nvidia.com/hostdev:  2
     pods:                250
   Allocatable:
     cpu:                 127500m
     ephemeral-storage:   1438028263499
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              262445732Ki
     nvidia.com/hostdev:  2
     pods:                250
   --
   Capacity:
     cpu:                 128
     ephemeral-storage:   1561525616Ki
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              263596704Ki
     nvidia.com/hostdev:  2
     pods:                250
   Allocatable:
     cpu:                 127500m
     ephemeral-storage:   1438028263499
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              262445728Ki
     nvidia.com/hostdev:  2
     pods:                250
   ```
5. Create a `HostDeviceNetwork` CR file:

   ```yaml
   $ cat <<EOF >  hostdev-network.yaml
   apiVersion: mellanox.com/v1alpha1
   kind: HostDeviceNetwork
   metadata:
     name: hostdev-net
   spec:
     networkNamespace: "default"
     resourceName: "hostdev"
     ipam: |
       {
         "type": "whereabouts",
         "range": "192.168.3.225/28",
         "exclude": [
          "192.168.3.229/30",
          "192.168.3.236/32"
         ]
       }
   EOF
   ```
6. Create the `HostDeviceNetwork` resource on the cluster by using the following command:

   ```terminal
   $ oc create -f hostdev-network.yaml
   ```

   ```terminal {title="Example output"}
   hostdevicenetwork.mellanox.com/hostdev-net created
   ```
7. Confirm that the resources appear in the cluster `oc describe node` section by using the following command:

   ```terminal
   $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A8
   ```

   ```terminal {title="Example output"}
   Capacity:
     cpu:                 128
     ephemeral-storage:   1561525616Ki
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              263596708Ki
     nvidia.com/gpu:      2
     nvidia.com/hostdev:  2
     pods:                250
   Allocatable:
     cpu:                 127500m
     ephemeral-storage:   1438028263499
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              262445732Ki
     nvidia.com/gpu:      2
     nvidia.com/hostdev:  2
     pods:                250
   --
   Capacity:
     cpu:                 128
     ephemeral-storage:   1561525616Ki
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              263596680Ki
     nvidia.com/gpu:      2
     nvidia.com/hostdev:  2
     pods:                250
   Allocatable:
     cpu:                 127500m
     ephemeral-storage:   1438028263499
     hugepages-1Gi:       0
     hugepages-2Mi:       0
     memory:              262445704Ki
     nvidia.com/gpu:      2
     nvidia.com/hostdev:  2
     pods:                250
   ```

### Creating a SR-IOV legacy mode RDMA on RoCE {#rdma-creating-sriov-legacy-mode-rdma-roce_rdma-remote-direct-memory-access}

Configure a Single Root I/O Virtualization (SR-IOV) legacy mode host device RDMA on RoCE.

**Procedure**

1. Generate a new host device `NicClusterPolicy` custom resource (CR):

   ```yaml
   $ cat <<EOF > network-sriovleg-nic-cluster-policy.yaml
   apiVersion: mellanox.com/v1alpha1
   kind: NicClusterPolicy
   metadata:
     name: nic-cluster-policy
   spec:
     ofedDriver:
       image: doca-driver
       repository: nvcr.io/nvidia/mellanox
       version: 24.10-0.7.0.0-0
       startupProbe:
         initialDelaySeconds: 10
         periodSeconds: 20
       livenessProbe:
         initialDelaySeconds: 30
         periodSeconds: 30
       readinessProbe:
         initialDelaySeconds: 10
         periodSeconds: 30
       env:
       - name: UNLOAD_STORAGE_MODULES
         value: "true"
       - name: RESTORE_DRIVER_ON_POD_TERMINATION
         value: "true"
       - name: CREATE_IFNAMES_UDEV
         value: "true"
   EOF
   ```
2. Create the policy on the cluster by using the following command:

   ```terminal
   $ oc create -f network-sriovleg-nic-cluster-policy.yaml
   ```

   ```terminal {title="Example output"}
   nicclusterpolicy.mellanox.com/nic-cluster-policy created
   ```
3. Verify the pods by using the following command in the DOCA/MOFED container:

   ```terminal
   $ oc get pods -n nvidia-network-operator
   ```

   ```terminal {title="Example output"}
   NAME                                                          READY   STATUS    RESTARTS      AGE
   mofed-rhcos4.16-696886fcb4-ds-4mb42                           2/2     Running   0             40s
   mofed-rhcos4.16-696886fcb4-ds-8knwq                           2/2     Running   0             40s
   nvidia-network-operator-controller-manager-68d547dbbd-qsdkf   1/1     Running   13 (4d ago)   4d21h
   ```
4. Create an `SriovNetworkNodePolicy` CR that generates the Virtual Functions (VFs) for the device you want to operate in SR-IOV legacy mode. See the following example:

   ```yaml
   $ cat <<EOF > sriov-network-node-policy.yaml
   apiVersion: sriovnetwork.openshift.io/v1
   kind: SriovNetworkNodePolicy
   metadata:
     name: sriov-legacy-policy
     namespace:  openshift-sriov-network-operator
   spec:
     deviceType: netdevice
     mtu: 1500
     nicSelector:
       vendor: "15b3"
       pfNames: ["ens8f0np0#0-7"]
     nodeSelector:
       feature.node.kubernetes.io/pci-15b3.present: "true"
     numVfs: 8
     priority: 90
     isRdma: true
     resourceName: sriovlegacy
   EOF
   ```
5. Create the CR on the cluster by using the following command:

   > [!NOTE]
   > Ensure that SR-IOV Global Enable is enabled. For more information, see [Unable to enable SR-IOV and receiving the message "not enough MMIO resources for SR-IOV" in Red Hat Enterprise Linux](https://access.redhat.com/solutions/37376).

   ```terminal
   $ oc create -f sriov-network-node-policy.yaml
   ```

   ```terminal {title="Example output"}
   sriovnetworknodepolicy.sriovnetwork.openshift.io/sriov-legacy-policy created
   ```
6. Each node has scheduling disabled. The nodes reboot to apply the configuration. You can view the nodes by using the following command:

   ```terminal
   $ oc get nodes
   ```

   ```terminal {title="Example output"}
   NAME                                       STATUS                        ROLES                         AGE     VERSION
   edge-19.edge.lab.eng.rdu2.redhat.com       Ready                         control-plane,master,worker   5d      v1.29.8+632b078
   nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com   Ready                         worker                        4d22h   v1.29.8+632b078
   nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com   NotReady,SchedulingDisabled   worker                        4d22h   v1.29.8+632b078
   ```
7. After the nodes have rebooted, verify that the VF interfaces exist by opening up a debug pod on each node. Run the following command:

   ```terminal
   a$ oc debug node/nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
   ```

   ```terminal {title="Example output"}
   Starting pod/nvd-srv-33nvidiaengrdu2dcredhatcom-debug-cqfjz ...
   To use host binaries, run `chroot /host`
   Pod IP: 10.6.135.12
   If you don't see a command prompt, try pressing enter.
   sh-5.1# chroot /host
   sh-5.1# ip link show | grep ens8
   26: ens8f0np0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
   42: ens8f0v0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   43: ens8f0v1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   44: ens8f0v2: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   45: ens8f0v3: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   46: ens8f0v4: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   47: ens8f0v5: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   48: ens8f0v6: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   49: ens8f0v7: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
   ```
8. Repeat the previous steps on the second node, if necessary.
9. Optional: Confirm that the resources appear in the cluster `oc describe node` section by using the following command:

   ```terminal
   $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A8
   ```

   ```terminal {title="Example output"}
   Capacity:
     cpu:                       128
     ephemeral-storage:         1561525616Ki
     hugepages-1Gi:             0
     hugepages-2Mi:             0
     memory:                    263596692Ki
     nvidia.com/gpu:            2
     nvidia.com/hostdev:        0
     openshift.io/sriovlegacy:  8
   --
   Allocatable:
     cpu:                       127500m
     ephemeral-storage:         1438028263499
     hugepages-1Gi:             0
     hugepages-2Mi:             0
     memory:                    262445716Ki
     nvidia.com/gpu:            2
     nvidia.com/hostdev:        0
     openshift.io/sriovlegacy:  8
   --
   Capacity:
     cpu:                       128
     ephemeral-storage:         1561525616Ki
     hugepages-1Gi:             0
     hugepages-2Mi:             0
     memory:                    263596688Ki
     nvidia.com/gpu:            2
     nvidia.com/hostdev:        0
     openshift.io/sriovlegacy:  8
   --
   Allocatable:
     cpu:                       127500m
     ephemeral-storage:         1438028263499
     hugepages-1Gi:             0
     hugepages-2Mi:             0
     memory:                    262445712Ki
     nvidia.com/gpu:            2
     nvidia.com/hostdev:        0
     openshift.io/sriovlegacy:  8
   ```
10. After the VFs for SR-IOV legacy mode are in place, generate the `SriovNetwork` CR file. See the following example:

    ```yaml
    $ cat <<EOF > sriov-network.yaml
    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetwork
    metadata:
      name: sriov-network
      namespace:  openshift-sriov-network-operator
    spec:
      vlan: 0
      networkNamespace: "default"
      resourceName: "sriovlegacy"
      ipam: |
        {
          "type": "whereabouts",
          "range": "192.168.3.225/28",
          "exclude": [
           "192.168.3.229/30",
           "192.168.3.236/32"
          ]
        }
    EOF
    ```
11. Create the custom resource on the cluster by using the following command:

    ```terminal
    $ oc create -f sriov-network.yaml
    ```

    ```terminal {title="Example output"}
    sriovnetwork.sriovnetwork.openshift.io/sriov-network created
    ```

### Creating a shared device RDMA on Infiniband {#rdma-creating-shared-device-rdma-ib_rdma-remote-direct-memory-access}

Create the workload pods for a shared device Remote Direct Memory Access (RDMA) for an Infiniband installation.

**Procedure**

1. Generate custom pod resources:

   ```yaml
   $ cat <<EOF > rdma-ib-32-workload.yaml
   apiVersion: v1
   kind: Pod
   metadata:
     name: rdma-ib-32-workload
     namespace: default
     annotations:
       k8s.v1.cni.cncf.io/networks: example-ipoibnetwork
   spec:
     nodeSelector:
       kubernetes.io/hostname: nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
     containers:
     - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
       name: rdma-ib-32-workload
       resources:
         limits:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_ib: 1
         requests:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_ib: 1
   EOF

   $ cat <<EOF > rdma-ib-32-workload.yaml
   apiVersion: v1
   kind: Pod
   metadata:
     name: rdma-ib-33-workload
     namespace: default
     annotations:
       k8s.v1.cni.cncf.io/networks: example-ipoibnetwork
   spec:
     nodeSelector:
       kubernetes.io/hostname: nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
     containers:
     - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
       name: rdma-ib-33-workload
       securityContext:
         capabilities:
           add: [ "IPC_LOCK" ]
       resources:
         limits:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_ib: 1
         requests:
           nvidia.com/gpu: 1
           rdma/rdma_shared_device_ib: 1
   EOF
   ```
2. Create the pods on the cluster by using the following commands:

   ```terminal
   $ oc create -f rdma-ib-32-workload.yaml
   ```

   ```terminal {title="Example output"}
   pod/rdma-ib-32-workload created
   ```

   ```terminal
   $ oc create -f rdma-ib-33-workload.yaml
   ```

   ```terminal {title="Example output"}
   pod/rdma-ib-33-workload created
   ```
3. Verify that the pods are running by using the following command:

   ```terminal
   $ oc get pods
   ```

   ```terminal {title="Example output"}
   NAME                  READY   STATUS    RESTARTS   AGE
   rdma-ib-32-workload   1/1     Running   0          10s
   rdma-ib-33-workload   1/1     Running   0          3s
   ```

## Verifying RDMA connectivity {#rdma-verifying-rdma-connectivity_rdma-remote-direct-memory-access}

Confirm Remote Direct Memory Access (RDMA) connectivity is working between the systems, specifically for Legacy Single Root I/O Virtualization (SR-IOV) Ethernet.

**Procedure**

1. Connect to each `rdma-workload-client` pod by using the following command:

   ```terminal
   $ oc rsh -n default rdma-sriov-32-workload
   ```

   ```terminal {title="Example output"}
   sh-5.1#
   ```
2. Check the IP address assigned to the first workload pod by using the following command. In this example, the first workload pod is the RDMA test server.

   ```terminal
   sh-5.1# ip a
   ```

   ```terminal {title="Example output"}
   1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
       link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
       inet 127.0.0.1/8 scope host lo
          valid_lft forever preferred_lft forever
       inet6 ::1/128 scope host
          valid_lft forever preferred_lft forever
   2: eth0@if3970: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1400 qdisc noqueue state UP group default
       link/ether 0a:58:0a:80:02:a7 brd ff:ff:ff:ff:ff:ff link-netnsid 0
       inet 10.128.2.167/23 brd 10.128.3.255 scope global eth0
          valid_lft forever preferred_lft forever
       inet6 fe80::858:aff:fe80:2a7/64 scope link
          valid_lft forever preferred_lft forever
   3843: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000
       link/ether 26:34:fd:53:a6:ec brd ff:ff:ff:ff:ff:ff
       altname enp55s0f0v5
       inet 192.168.4.225/28 brd 192.168.4.239 scope global net1
          valid_lft forever preferred_lft forever
       inet6 fe80::2434:fdff:fe53:a6ec/64 scope link
          valid_lft forever preferred_lft forever
   sh-5.1#
   ```

   The IP address of the RDMA server assigned to this pod is the `net1` interface. In this example, the IP address is `192.168.4.225`.
3. Run the `ibstatus` command to get the `link_layer` type, Ethernet or Infiniband, associated with each RDMA device `mlx5_x`.  The output also shows the status of all of the RDMA devices by checking the `state` field, which shows either `ACTIVE` or `DOWN`.

   ```terminal
   sh-5.1# ibstatus
   ```

   ```terminal {title="Example output"}
   Infiniband device 'mlx5_0' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_1' port 1 status:
   	default gid:	 fe80:0000:0000:0000:e8eb:d303:0072:1415
   	base lid:	 0xc
   	sm lid:		 0x1
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 InfiniBand

   Infiniband device 'mlx5_2' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_3' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_4' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_5' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_6' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_7' port 1 status:
   	default gid:	 fe80:0000:0000:0000:2434:fdff:fe53:a6ec
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_8' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_9' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   sh-5.1#
   ```
4. To get the `link_layer` for each RDMA `mlx5` device on your worker node, run the `ibstat` command:

   ```terminal
   sh-5.1# ibstat | egrep "Port|Base|Link"
   ```

   ```terminal {title="Example output"}
   Port 1:
   		Physical state: LinkUp
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Physical state: LinkUp
   		Base lid: 12
   		Port GUID: 0xe8ebd30300721415
   		Link layer: InfiniBand
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Physical state: LinkUp
   		Base lid: 0
   		Port GUID: 0x2434fdfffe53a6ec
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   	Port 1:
   		Base lid: 0
   		Port GUID: 0x0000000000000000
   		Link layer: Ethernet
   sh-5.1#
   ```
5. For RDMA Shared Device or Host Device workload pods, the RDMA device named `mlx5_x` is already known and is typically `mlx5_0` or `mlx5_1`. For RDMA Legacy SR-IOV workload pods, you need to determine which RDMA device is associated with which Virtual Function (VF) subinterface. Provide this information by using the following command:

   ```terminal
   sh-5.1# rdma link show
   ```

   ```terminal {title="Example output"}
   link mlx5_0/1 state ACTIVE physical_state LINK_UP
   link mlx5_1/1 subnet_prefix fe80:0000:0000:0000 lid 12 sm_lid 1 lmc 0 state ACTIVE physical_state LINK_UP
   link mlx5_2/1 state DOWN physical_state DISABLED
   link mlx5_3/1 state DOWN physical_state DISABLED
   link mlx5_4/1 state DOWN physical_state DISABLED
   link mlx5_5/1 state DOWN physical_state DISABLED
   link mlx5_6/1 state DOWN physical_state DISABLED
   link mlx5_7/1 state ACTIVE physical_state LINK_UP netdev net1
   link mlx5_8/1 state DOWN physical_state DISABLED
   link mlx5_9/1 state DOWN physical_state DISABLED
   ```

   In this example, the RDMA device names `mlx5_7` is associated with the `net1` interface. This output is used in the next command to perform the RDMA bandwidth test, which also verifies RDMA connectivity between worker nodes.
6. Run the following `ib_write_bw` RDMA bandwidth test command:

   ```terminal
   sh-5.1# /root/perftest/ib_write_bw -R -T 41 -s 65536 -F -x 3 -m 4096 --report_gbits -q 16 -D 60  -d mlx5_7 -p 10000 --source_ip  192.168.4.225 --use_cuda=0 --use_cuda_dmabuf
   ```

   where:

   - The `mlx5_7` RDMA device is passed in the `-d` switch.
   - The source IP address is `192.168.4.225` to start the RDMA server.
   - The `--use_cuda=0`, `--use_cuda_dmabuf` switches indicate that the use of GPUDirect RDMA.

     ```terminal {title="Example output"}
     WARNING: BW peak won't be measured in this run.
     Perftest doesn't supports CUDA tests with inline messages: inline size set to 0

     ************************************
     * Waiting for client to connect... *
     ************************************
     ```
7. Open another terminal window and run `oc rsh` command on the second workload pod that acts as the RDMA test client pod:

   ```terminal
   $ oc rsh -n default rdma-sriov-33-workload
   ```

   ```terminal {title="Example output"}
   sh-5.1#
   ```
8. Obtain the RDMA test client pod IP address from the `net1` interface by using the following command:

   ```terminal
   sh-5.1# ip a
   ```

   ```terminal {title="Example output"}
   1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
       link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
       inet 127.0.0.1/8 scope host lo
          valid_lft forever preferred_lft forever
       inet6 ::1/128 scope host
          valid_lft forever preferred_lft forever
   2: eth0@if4139: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1400 qdisc noqueue state UP group default
       link/ether 0a:58:0a:83:01:d5 brd ff:ff:ff:ff:ff:ff link-netnsid 0
       inet 10.131.1.213/23 brd 10.131.1.255 scope global eth0
          valid_lft forever preferred_lft forever
       inet6 fe80::858:aff:fe83:1d5/64 scope link
          valid_lft forever preferred_lft forever
   4076: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000
       link/ether 56:6c:59:41:ae:4a brd ff:ff:ff:ff:ff:ff
       altname enp55s0f0v0
       inet 192.168.4.226/28 brd 192.168.4.239 scope global net1
          valid_lft forever preferred_lft forever
       inet6 fe80::546c:59ff:fe41:ae4a/64 scope link
          valid_lft forever preferred_lft forever
   sh-5.1#
   ```
9. Obtain the `link_layer` type associated with each RDMA device `mlx5_x` by using the following command:

   ```terminal
   sh-5.1# ibstatus
   ```

   ```terminal {title="Example output"}
   Infiniband device 'mlx5_0' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_1' port 1 status:
   	default gid:	 fe80:0000:0000:0000:e8eb:d303:0072:09f5
   	base lid:	 0xd
   	sm lid:		 0x1
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 InfiniBand

   Infiniband device 'mlx5_2' port 1 status:
   	default gid:	 fe80:0000:0000:0000:546c:59ff:fe41:ae4a
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 4: ACTIVE
   	phys state:	 5: LinkUp
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_3' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_4' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_5' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_6' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_7' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_8' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet

   Infiniband device 'mlx5_9' port 1 status:
   	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
   	base lid:	 0x0
   	sm lid:		 0x0
   	state:		 1: DOWN
   	phys state:	 3: Disabled
   	rate:		 200 Gb/sec (4X HDR)
   	link_layer:	 Ethernet
   ```
10. Optional: Obtain the firmware version of Mellanox cards by using the `ibstat` command:

    ```terminal
    sh-5.1# ibstat
    ```

    ```terminal {title="Example output"}
    CA 'mlx5_0'
    	CA type: MT4123
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xe8ebd303007209f4
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_1'
    	CA type: MT4123
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xe8ebd303007209f5
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 13
    		LMC: 0
    		SM lid: 1
    		Capability mask: 0xa651e848
    		Port GUID: 0xe8ebd303007209f5
    		Link layer: InfiniBand
    CA 'mlx5_2'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x566c59fffe41ae4a
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x546c59fffe41ae4a
    		Link layer: Ethernet
    CA 'mlx5_3'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xb2ae4bfffe8f3d02
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_4'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x2a9967fffe8bf272
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_5'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x5aff2ffffe2e17e8
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_6'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x121bf1fffe074419
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_7'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xb22b16fffed03dd7
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_8'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x523800fffe16d105
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_9'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xd2b4a1fffebdc4a9
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    sh-5.1#
    ```
11. To determine which RDMA device is associated with the Virtual Function subinterface that the client workload pod uses, run the following command. In this example, the `net1` interface is using the RDMA device `mlx5_2`.

    ```terminal
    sh-5.1# rdma link show
    ```

    ```terminal {title="Example output"}
    link mlx5_0/1 state ACTIVE physical_state LINK_UP
    link mlx5_1/1 subnet_prefix fe80:0000:0000:0000 lid 13 sm_lid 1 lmc 0 state ACTIVE physical_state LINK_UP
    link mlx5_2/1 state ACTIVE physical_state LINK_UP netdev net1
    link mlx5_3/1 state DOWN physical_state DISABLED
    link mlx5_4/1 state DOWN physical_state DISABLED
    link mlx5_5/1 state DOWN physical_state DISABLED
    link mlx5_6/1 state DOWN physical_state DISABLED
    link mlx5_7/1 state DOWN physical_state DISABLED
    link mlx5_8/1 state DOWN physical_state DISABLED
    link mlx5_9/1 state DOWN physical_state DISABLED
    sh-5.1#
    ```
12. Run the following `ib_write_bw` RDMA bandwidth test command:

    ```terminal
    sh-5.1# /root/perftest/ib_write_bw -R -T 41 -s 65536 -F -x 3 -m 4096 --report_gbits -q 16 -D 60  -d mlx5_2 -p 10000 --source_ip  192.168.4.226 --use_cuda=0 --use_cuda_dmabuf 192.168.4.225
    ```

    where:

    - The `mlx5_2` RDMA device is passed in the `-d` switch.
    - The source IP address `192.168.4.226` and the destination IP address of the RDMA server `192.168.4.225`.
    - The `--use_cuda=0`, `--use_cuda_dmabuf` switches indicate that the use of GPUDirect RDMA.

      ```terminal {title="Example output"}
      WARNING: BW peak won't be measured in this run.
      Perftest doesn't supports CUDA tests with inline messages: inline size set to 0
      Requested mtu is higher than active mtu
      Changing to active mtu - 3
      initializing CUDA
      Listing all CUDA devices in system:
      CUDA device 0: PCIe address is 61:00

      Picking device No. 0
      [pid = 8909, dev = 0] device name = [NVIDIA A40]
      creating CUDA Ctx
      making it the current CUDA Ctx
      CUDA device integrated: 0
      using DMA-BUF for GPU buffer address at 0x7f8738600000 aligned at 0x7f8738600000 with aligned size 2097152
      allocated GPU buffer of a 2097152 address at 0x23a7420 for type CUDA_MEM_DEVICE
      Calling ibv_reg_dmabuf_mr(offset=0, size=2097152, addr=0x7f8738600000, fd=40) for QP #0
      ---------------------------------------------------------------------------------------
                          RDMA_Write BW Test
       Dual-port       : OFF		Device         : mlx5_2
       Number of qps   : 16		Transport type : IB
       Connection type : RC		Using SRQ      : OFF
       PCIe relax order: ON		Lock-free      : OFF
       ibv_wr* API     : ON		Using DDP      : OFF
       TX depth        : 128
       CQ Moderation   : 1
       CQE Poll Batch  : 16
       Mtu             : 1024[B]
       Link type       : Ethernet
       GID index       : 3
       Max inline data : 0[B]
       rdma_cm QPs	 : ON
       Data ex. method : rdma_cm 	TOS    : 41
      ---------------------------------------------------------------------------------------
       local address: LID 0000 QPN 0x012d PSN 0x3cb6d7
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x012e PSN 0x90e0ac
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x012f PSN 0x153f50
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0130 PSN 0x5e0128
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0131 PSN 0xd89752
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0132 PSN 0xe5fc16
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0133 PSN 0x236787
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0134 PSN 0xd9273e
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0135 PSN 0x37cfd4
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0136 PSN 0x3bff8f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0137 PSN 0x81f2bd
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0138 PSN 0x575c43
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0139 PSN 0x6cf53d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013a PSN 0xcaaf6f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013b PSN 0x346437
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013c PSN 0xcc5865
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x026d PSN 0x359409
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x026e PSN 0xe387bf
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x026f PSN 0x5be79d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0270 PSN 0x1b4b28
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0271 PSN 0x76a61b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0272 PSN 0x3d50e1
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0273 PSN 0x1b572c
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0274 PSN 0x4ae1b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0275 PSN 0x5591b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0276 PSN 0xfa2593
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0277 PSN 0xd9473b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0278 PSN 0x2116b2
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0279 PSN 0x9b83b6
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027a PSN 0xa0822b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027b PSN 0x6d930d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027c PSN 0xb1a4d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
      ---------------------------------------------------------------------------------------
       #bytes     #iterations    BW peak[Gb/sec]    BW average[Gb/sec]   MsgRate[Mpps]
       65536      10329004         0.00               180.47 		     0.344228
      ---------------------------------------------------------------------------------------
      deallocating GPU buffer 00007f8738600000
      destroying current CUDA Ctx
      sh-5.1#
      ```

      A positive test is seeing an expected BW average and MsgRate in Mpps.

      Upon completion of the `ib_write_bw` command, the server side output also appears on the server pod. See the following example:

      ```terminal {title="Example output"}
      WARNING: BW peak won't be measured in this run.
      Perftest doesn't supports CUDA tests with inline messages: inline size set to 0

      ************************************
      * Waiting for client to connect... *
      ************************************
      Requested mtu is higher than active mtu
      Changing to active mtu - 3
      initializing CUDA
      Listing all CUDA devices in system:
      CUDA device 0: PCIe address is 61:00

      Picking device No. 0
      [pid = 9226, dev = 0] device name = [NVIDIA A40]
      creating CUDA Ctx
      making it the current CUDA Ctx
      CUDA device integrated: 0
      using DMA-BUF for GPU buffer address at 0x7f447a600000 aligned at 0x7f447a600000 with aligned size 2097152
      allocated GPU buffer of a 2097152 address at 0x2406400 for type CUDA_MEM_DEVICE
      Calling ibv_reg_dmabuf_mr(offset=0, size=2097152, addr=0x7f447a600000, fd=40) for QP #0
      ---------------------------------------------------------------------------------------
                          RDMA_Write BW Test
       Dual-port       : OFF		Device         : mlx5_7
       Number of qps   : 16		Transport type : IB
       Connection type : RC		Using SRQ      : OFF
       PCIe relax order: ON		Lock-free      : OFF
       ibv_wr* API     : ON		Using DDP      : OFF
       CQ Moderation   : 1
       CQE Poll Batch  : 16
       Mtu             : 1024[B]
       Link type       : Ethernet
       GID index       : 3
       Max inline data : 0[B]
       rdma_cm QPs	 : ON
       Data ex. method : rdma_cm 	TOS    : 41
      ---------------------------------------------------------------------------------------
       Waiting for client rdma_cm QP to connect
       Please run the same command with the IB/RoCE interface IP
      ---------------------------------------------------------------------------------------
       local address: LID 0000 QPN 0x026d PSN 0x359409
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x026e PSN 0xe387bf
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x026f PSN 0x5be79d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0270 PSN 0x1b4b28
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0271 PSN 0x76a61b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0272 PSN 0x3d50e1
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0273 PSN 0x1b572c
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0274 PSN 0x4ae1b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0275 PSN 0x5591b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0276 PSN 0xfa2593
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0277 PSN 0xd9473b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0278 PSN 0x2116b2
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0279 PSN 0x9b83b6
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027a PSN 0xa0822b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027b PSN 0x6d930d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027c PSN 0xb1a4d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x012d PSN 0x3cb6d7
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x012e PSN 0x90e0ac
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x012f PSN 0x153f50
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0130 PSN 0x5e0128
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0131 PSN 0xd89752
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0132 PSN 0xe5fc16
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0133 PSN 0x236787
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0134 PSN 0xd9273e
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0135 PSN 0x37cfd4
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0136 PSN 0x3bff8f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0137 PSN 0x81f2bd
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0138 PSN 0x575c43
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0139 PSN 0x6cf53d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013a PSN 0xcaaf6f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013b PSN 0x346437
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013c PSN 0xcc5865
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
      ---------------------------------------------------------------------------------------
       #bytes     #iterations    BW peak[Gb/sec]    BW average[Gb/sec]   MsgRate[Mpps]
       65536      10329004         0.00               180.47 		     0.344228
      ---------------------------------------------------------------------------------------
      deallocating GPU buffer 00007f447a600000
      destroying current CUDA Ctx
      ```