title: Configuring an SR-IOV network device
---

# Configuring an SR-IOV network device {#configuring-sriov-device}

You can configure a Single Root I/O Virtualization (SR-IOV) device in your cluster.

Before you perform any tasks in the following documentation, ensure that you [installed the SR-IOV Network Operator](/openshift-docs-markdown/networking/networking_operators/sr-iov-operator/installing-sriov-operator#installing-sriov-operator).

## SR-IOV network node configuration object {#nw-sriov-networknodepolicy-object_configuring-sriov-device}

You specify the SR-IOV network device configuration for a node by creating an SR-IOV network node policy. The API object for the policy is part of the `sriovnetwork.openshift.io` API group.

The following YAML describes an SR-IOV network node policy:

```yaml
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: <name>
  namespace: openshift-sriov-network-operator
spec:
  resourceName: <sriov_resource_name>
  nodeSelector:
    feature.node.kubernetes.io/network-sriov.capable: "true"
  priority: <priority>
  mtu: <mtu>
  needVhostNet: false
  numVfs: <num>
  externallyManaged: false
  nicSelector:
    vendor: "<vendor_code>"
    deviceID: "<device_id>"
    pfNames: ["<pf_name>", ...]
    rootDevices: ["<pci_bus_id>", ...]
    netFilter: "<filter_string>"
  deviceType: <device_type>
  isRdma: false
  linkType: <link_type>
  eSwitchMode: "switchdev"
  excludeTopology: false
```

where:

`metadata.name`
:   Specifies the name for the custom resource object.

`metadata.namespace`
:   Specifies the namespace where the SR-IOV Network Operator is installed.

`spec.resourceName`
:   Specifies the resource name of the SR-IOV network device plugin. You can create multiple SR-IOV network node policies for a resource name. When specifying a name, be sure to use the accepted syntax expression `^[a-zA-Z0-9_]+$`.

`spec.nodeSelector`
:   Specifies the nodes to configure. Only SR-IOV network devices on the selected nodes are configured. The SR-IOV Container Network Interface (CNI) plugin and device plugin are deployed on selected nodes only.

    > [!IMPORTANT]
    > The SR-IOV Network Operator applies node network configuration policies to nodes in sequence. Before applying node network configuration policies, the SR-IOV Network Operator checks if the machine config pool (MCP) for a node is in an unhealthy state such as `Degraded` or `Updating`. If a node is in an unhealthy MCP, the process of applying node network configuration policies to all targeted nodes in the cluster pauses until the MCP returns to a healthy state.
    >
    > To avoid a node in an unhealthy MCP from blocking the application of node network configuration policies to other nodes, including nodes in other MCPs, you must create a separate node network configuration policy for each MCP.

`spec.priority`
:   Optional: Specifies the priority as an integer value between `0` and `99`. A smaller value receives higher priority. For example, a priority of `10` is a higher priority than `99`. The default value is `99`.

`spec.mtu`
:   Optional: Specifies the maximum transmission unit (MTU) of the physical function and all its virtual functions. The maximum MTU value can vary for different network interface controller (NIC) models.

    > [!IMPORTANT]
    > If you want to create virtual function on the default network interface, ensure that the MTU is set to a value that matches the cluster MTU.
    >
    > If you want to modify the MTU of a single virtual function while the function is assigned to a pod, leave the MTU value blank in the SR-IOV network node policy. Otherwise, the SR-IOV Network Operator reverts the MTU of the virtual function to the MTU value defined in the SR-IOV network node policy, which might trigger a node drain.

`spec.needVhostNet`
:   Optional: Set to `true` to mount the `/dev/vhost-net` device in the pod. Use the mounted `/dev/vhost-net` device with Data Plane Development Kit (DPDK) to forward traffic to the kernel network stack.

`spec.numVfs`
:   Specifies the number of the virtual functions (VF) to create for the SR-IOV physical network device. For an Intel network interface controller (NIC), the number of VFs cannot be larger than the total VFs supported by the device. For a Mellanox NIC, the number of VFs cannot be larger than `127`.

`spec.externallyManaged`
:   Indicates whether the SR-IOV Network Operator manages all, or only a subset of virtual functions (VFs). With the value set to `false` the SR-IOV Network Operator manages and configures all VFs on the PF.

    > [!NOTE]
    > When `externallyManaged` is set to `true`, you must manually create the Virtual Functions (VFs) on the physical function (PF) before applying the `SriovNetworkNodePolicy` resource. If the VFs are not pre-created, the SR-IOV Network Operator’s webhook will block the policy request.
    >
    > When `externallyManaged` is set to `false`, the SR-IOV Network Operator automatically creates and manages the VFs, including resetting them if necessary.
    >
    > To use VFs on the host system, you must create them through NMState, and set `externallyManaged` to `true`. In this mode, the SR-IOV Network Operator does not modify the PF or the manually managed VFs, except for those explicitly defined in the `nicSelector` field of your policy. However, the SR-IOV Network Operator continues to manage VFs that are used as pod secondary interfaces.

`spec.nicSelector`
:   Identifies the device to which this resource applies. You do not have to specify values for all the parameters. It is recommended to identify the network device with enough precision to avoid selecting a device unintentionally.

    If you specify `rootDevices`, you must also specify a value for `vendor`, `deviceID`, or `pfNames`. If you specify both `pfNames` and `rootDevices` at the same time, ensure that they refer to the same device. If you specify a value for `netFilter`, then you do not need to specify any other parameter because a network ID is unique.

`spec.nicSelector.vendor`
:   Optional: Specifies the vendor hexadecimal identifier of the SR-IOV network device. The only allowed values are `8086` (Intel) and `15b3` (Mellanox).

`spec.nicSelector.deviceID`
:   Optional: Specifies the device hexadecimal identifier of the SR-IOV network device. For example, `101b` is the device ID for a Mellanox ConnectX-6 device.

`spec.nicSelector.pfNames`
:   Optional: Specifies an array of one or more physical function (PF) names the resource must apply to. You can specify either the kernel-assigned interface name or an alternative name configured through the Kubernetes NMState Operator.

`spec.nicSelector.rootDevices`
:   Optional: Specifies an array of one or more PCI bus addresses the resource must apply to. For example `0000:02:00.1`.

`spec.nicSelector.netFilter`
:   Optional: Specifies the platform-specific network filter. The only supported platform is Red Hat OpenStack Platform (RHOSP). Acceptable values use the following format: `openstack/NetworkID:xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx`. Replace `xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx` with the value from the `/var/config/openstack/latest/network_data.json` metadata file. This filter ensures that VFs are associated with a specific OpenStack network. The operator uses this filter to map the VFs to the appropriate network based on metadata provided by the OpenStack platform.

`spec.deviceType`
:   Optional: Specifies the driver to configure for the VFs created from this resource. The only allowed values are `netdevice` and `vfio-pci`. The default value is `netdevice`.

    For a Mellanox NIC to work in DPDK mode on bare-metal nodes, use the `netdevice` driver type and set `isRdma` to `true`.

`spec.isRdma`
:   Optional: Configures whether to enable remote direct memory access (RDMA) mode. The default value is `false`.

    If the `isRdma` parameter is set to `true`, you can continue to use the RDMA-enabled VF as a normal network device. A device can be used in either mode.

    Set `isRdma` to `true` and additionally set `needVhostNet` to `true` to configure a Mellanox NIC for use with Fast data path DPDK applications.

    > [!NOTE]
    > You cannot set the `isRdma` parameter to `true` for Intel NICs.

`spec.linkType`
:   Optional: Specifies the link type for the VFs. The default value is `eth` for Ethernet. Change this value to 'ib' for InfiniBand.

    When `linkType` is set to `ib`, `isRdma` is automatically set to `true` by the SR-IOV Network Operator webhook. When `linkType` is set to `ib`, `deviceType` should not be set to `vfio-pci`.

    Do not set `linkType` to `eth` for `SriovNetworkNodePolicy`, because this can lead to an incorrect number of available devices reported by the device plugin.

`spec.eSwitchMode`
:   Optional: Set to `"switchdev"` to enable hardware offloading. For more information about hardware offloading, see "Configuring hardware offloading".

`spec.excludeTopology`
:   Optional: Set to `true` to exclude advertising an SR-IOV network resource’s NUMA node to the Topology Manager. The default value is `false`.

### SR-IOV network node configuration examples {#nw-sr-iov-network-node-configuration-examples_configuring-sriov-device}

The following example describes the configuration for an InfiniBand device:

```yaml {title="Example configuration for an InfiniBand device"}
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: <name>
  namespace: openshift-sriov-network-operator
spec:
  resourceName: <sriov_resource_name>
  nodeSelector:
    feature.node.kubernetes.io/network-sriov.capable: "true"
  numVfs: <num>
  nicSelector:
    vendor: "<vendor_code>"
    deviceID: "<device_id>"
    rootDevices:
      - "<pci_bus_id>"
  linkType: <link_type>
  isRdma: true
# ...
```

The following example describes the configuration for an SR-IOV network device in a RHOSP virtual machine:

```yaml {title="Example configuration for an SR-IOV device in a virtual machine"}
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: <name>
  namespace: openshift-sriov-network-operator
spec:
  resourceName: <sriov_resource_name>
  nodeSelector:
    feature.node.kubernetes.io/network-sriov.capable: "true"
  numVfs: 1
  nicSelector:
    vendor: "<vendor_code>"
    deviceID: "<device_id>"
    netFilter: "openstack/NetworkID:ea24bd04-8674-4f69-b0ee-fa0b3bd20509"
# ...
```

- When configuring the node network policy for a virtual machine, the `numVfs` parameter is always set to `1`.
- When the virtual machine is deployed on RHOSP, the `netFilter` parameter must refer to a network ID. Valid values for `netFilter` are available from an `SriovNetworkNodeState` object.

### Automated discovery of SR-IOV network devices {#discover-sr-iov-devices_configuring-sriov-device}

The SR-IOV Network Operator searches your cluster for SR-IOV capable network devices on worker nodes. The Operator creates and updates a `SriovNetworkNodeState` custom resource (CR) for each worker node that provides a compatible SR-IOV network device.

The CR is assigned the same name as the worker node. The `status.interfaces` list provides information about the network devices on a node.

> [!IMPORTANT]
> Do not modify a `SriovNetworkNodeState` object. The Operator creates and manages these resources automatically.

The following YAML is an example of a `SriovNetworkNodeState` object created by the SR-IOV Network Operator:

```yaml
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodeState
metadata:
  name: node-25
  namespace: openshift-sriov-network-operator
  ownerReferences:
  - apiVersion: sriovnetwork.openshift.io/v1
    blockOwnerDeletion: true
    controller: true
    kind: SriovNetworkNodePolicy
    name: default
spec:
  dpConfigVersion: "39824"
status:
  interfaces:
  - deviceID: "1017"
    driver: mlx5_core
    mtu: 1500
    name: ens785f0
    altNames:
    - production-nic
    pciAddress: "0000:18:00.0"
    totalvfs: 8
    vendor: 15b3
  - deviceID: "1017"
    driver: mlx5_core
    mtu: 1500
    name: ens785f1
    pciAddress: "0000:18:00.1"
    totalvfs: 8
    vendor: 15b3
  - deviceID: 158b
    driver: i40e
    mtu: 1500
    name: ens817f0
    pciAddress: 0000:81:00.0
    totalvfs: 64
    vendor: "8086"
  - deviceID: 158b
    driver: i40e
    mtu: 1500
    name: ens817f1
    pciAddress: 0000:81:00.1
    totalvfs: 64
    vendor: "8086"
  - deviceID: 158b
    driver: i40e
    mtu: 1500
    name: ens803f0
    pciAddress: 0000:86:00.0
    totalvfs: 64
    vendor: "8086"
  syncStatus: Succeeded
```

- The value of the `name` field is the same as the name of the worker node.
- The `interfaces` stanza includes a list of all of the SR-IOV devices discovered by the Operator on the worker node.
- The `altNames` field lists any alternative interface names configured through the Kubernetes NMState Operator. You can use these names in the `nicSelector.pfNames` field of a `SriovNetworkNodePolicy` CR.

### Configuring the SR-IOV Network Operator on Mellanox cards when Secure Boot is enabled {#nw-sriov-nic-mlx-secure-boot_configuring-sriov-device}

The SR-IOV Network Operator supports an option to skip the firmware configuration for Mellanox devices. This option allows you to create virtual functions by using the SR-IOV Network Operator when the system has secure boot enabled. You must manually configure and allocate the number of virtual functions in the firmware before switching the system to secure boot.

> [!NOTE]
> The number of virtual functions in the firmware is the maximum number of virtual functions that you can request in the policy.

**Procedure**

1. Configure the virtual functions (VFs) by running the following command when the system is without a secure boot when using the sriov-config daemon:

   ```terminal
   $ mstconfig -d -0001:b1:00.1 set SRIOV_EN=1 NUM_OF_VFS=16
   ```

   - `SRIOV_EN=1` enables the SR-IOV Network Operator support on the Mellanox card.
   - `NUM_OF_VFS=16` specifies the number of virtual functions to enable in the firmware.
2. Configure the SR-IOV Network Operator by disabling the Mellanox plugin. See the following `SriovOperatorConfig` example configuration:

   ```yaml
   apiVersion: sriovnetwork.openshift.io/v1
   kind: SriovOperatorConfig
   metadata:
     name: default
     namespace: openshift-sriov-network-operator
   spec:
     configDaemonNodeSelector: {}
     configurationMode: daemon
     disableDrain: false
     disablePlugins:
     - mellanox
     enableInjector: true
     enableOperatorWebhook: true
     logLevel: 2
   ```
3. Reboot the system to enable the virtual functions and the configuration settings.
4. Check the virtual functions (VFs) after rebooting the system by running the following command:

   ```terminal
   $ oc -n openshift-sriov-network-operator get sriovnetworknodestate.sriovnetwork.openshift.io worker-0 -oyaml
   ```

   The following is example output:

   ```yaml
   - deviceID: 101d
       driver: mlx5_core
       eSwitchMode: legacy
       linkSpeed: -1 Mb/s
       linkType: ETH
       mac: 08:c0:eb:96:31:25
       mtu: 1500
       name: ens3f1np1
       pciAddress: 0000:b1:00.1
       totalvfs: 16
       vendor: 15b3
   ```

   - The `totalvfs` value is the same number used in the `mstconfig` command earlier in the procedure.
5. Enable secure boot to prevent unauthorized operating systems and malicious software from loading during the device’s boot process.

   1. Enable secure boot by using the BIOS (Basic Input/Output System) to set values for the following parameters:

      - `Secure Boot: Enabled`
      - `Secure Boot Policy: Standard`
      - `Secure Boot Mode: Mode Deployed`
   2. Reboot the system.

### Virtual function (VF) partitioning for SR-IOV devices {#nw-sriov-nic-partitioning_configuring-sriov-device}

In some cases, you might want to split virtual functions (VFs) from the same physical function (PF) into many resource pools. For example, you might want some of the VFs to load with the default driver and the remaining VFs load with the `vfio-pci` driver.

For example, the following YAML shows the selector for an interface named `netpf0` with VF `2` through `7`:

```yaml
pfNames: ["netpf0#2-7"]
```

where:

`netpf0`
:   The name of the PF interface name.

`2`
:   The first VF index (0-based) that gets included in the range.

`7`
:   The last VF index (0-based) that gets included in the range.

You can select VFs from the same PF by using different policy CRs provided that you meet the following requirements:

- The `numVfs` value must be similar for policies that select the same PF.
- The VF index must be in the range of `0` to `<numVfs>-1`. For example, if you have a policy with `numVfs` set to `8`, then the `<first_vf>` value must not be smaller than `0`, and the `<last_vf>` must not be larger than `7`.
- The VFs ranges in different policies must not overlap.
- The `<first_vf>` must not be larger than the `<last_vf>`.

The following example illustrates NIC partitioning for an SR-IOV device.

The policy `policy-net-1` defines a resource pool `net-1` that includes the VF `0` of PF `netpf0` with the default VF driver. The policy `policy-net-1-dpdk` defines a resource pool `net-1-dpdk` that includes the VF `8` to `15` of PF `netpf0` with the `vfio` VF driver.

Policy `policy-net-1`:

```yaml
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: policy-net-1
  namespace: openshift-sriov-network-operator
spec:
  resourceName: net1
  nodeSelector:
    feature.node.kubernetes.io/network-sriov.capable: "true"
  numVfs: 16
  nicSelector:
    pfNames: ["netpf0#0-0"]
  deviceType: netdevice
```

Policy `policy-net-1-dpdk`:

```yaml
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
  name: policy-net-1-dpdk
  namespace: openshift-sriov-network-operator
spec:
  resourceName: net1dpdk
  nodeSelector:
    feature.node.kubernetes.io/network-sriov.capable: "true"
  numVfs: 16
  nicSelector:
    pfNames: ["netpf0#8-15"]
  deviceType: vfio-pci
```

#### Verifying that the interface is successfully partitioned {#_verifying_that_the_interface_is_successfully_partitioned}

Confirm that the interface partitioned to virtual functions (VFs) for the SR-IOV device by running the following command:

```terminal
$ ip link show <interface>
```

`<interface>` specifies the interface that you specified when partitioning to VFs for the SR-IOV device, for example, `ens3f1`.

The following is example output:

```terminal
5: ens3f1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
link/ether 3c:fd:fe:d1:bc:01 brd ff:ff:ff:ff:ff:ff

vf 0     link/ether 5a:e7:88:25:ea:a0 brd ff:ff:ff:ff:ff:ff, spoof checking on, link-state auto, trust off
vf 1     link/ether 3e:1d:36:d7:3d:49 brd ff:ff:ff:ff:ff:ff, spoof checking on, link-state auto, trust off
vf 2     link/ether ce:09:56:97:df:f9 brd ff:ff:ff:ff:ff:ff, spoof checking on, link-state auto, trust off
vf 3     link/ether 5e:91:cf:88:d1:38 brd ff:ff:ff:ff:ff:ff, spoof checking on, link-state auto, trust off
vf 4     link/ether e6:06:a1:96:2f:de brd ff:ff:ff:ff:ff:ff, spoof checking on, link-state auto, trust off
```

### A test pod template for clusters that use SR-IOV on OpenStack {#nw-openstack-ovs-sr-iov-testpmd-pod_configuring-sriov-device}

The following `testpmd` pod demonstrates container creation with huge pages, reserved CPUs, and the SR-IOV port.

```yaml {title="An example testpmd pod"}
apiVersion: v1
kind: Pod
metadata:
  name: testpmd-sriov
  namespace: mynamespace
  annotations:
    cpu-load-balancing.crio.io: "disable"
    cpu-quota.crio.io: "disable"
# ...
spec:
  containers:
  - name: testpmd
    command: ["sleep", "99999"]
    image: registry.redhat.io/openshift4/dpdk-base-rhel8:v4.9
    securityContext:
      capabilities:
        add: ["IPC_LOCK","SYS_ADMIN"]
      privileged: true
      runAsUser: 0
    resources:
      requests:
        memory: 1000Mi
        hugepages-1Gi: 1Gi
        cpu: '2'
        openshift.io/sriov1: 1
      limits:
        hugepages-1Gi: 1Gi
        cpu: '2'
        memory: 1000Mi
        openshift.io/sriov1: 1
    volumeMounts:
      - mountPath: /dev/hugepages
        name: hugepage
        readOnly: False
  runtimeClassName: performance-cnf-performanceprofile
  volumes:
  - name: hugepage
    emptyDir:
      medium: HugePages
```

- This example assumes that the name of the performance profile is `cnf-performance profile`.

### A test pod template for clusters that use OVS hardware offloading on OpenStack {#nw-openstack-hw-offload-testpmd-pod_configuring-sriov-device}

The following `testpmd` pod demonstrates Open vSwitch (OVS) hardware offloading on Red Hat OpenStack Platform (RHOSP).

```yaml {title="An example testpmd pod"}
apiVersion: v1
kind: Pod
metadata:
  name: testpmd-sriov
  namespace: mynamespace
  annotations:
    k8s.v1.cni.cncf.io/networks: hwoffload1
spec:
  runtimeClassName: performance-cnf-performanceprofile
  containers:
  - name: testpmd
    command: ["sleep", "99999"]
    image: registry.redhat.io/openshift4/dpdk-base-rhel8:v4.9
    securityContext:
      capabilities:
        add: ["IPC_LOCK","SYS_ADMIN"]
      privileged: true
      runAsUser: 0
    resources:
      requests:
        memory: 1000Mi
        hugepages-1Gi: 1Gi
        cpu: '2'
      limits:
        hugepages-1Gi: 1Gi
        cpu: '2'
        memory: 1000Mi
    volumeMounts:
      - mountPath: /mnt/huge
        name: hugepage
        readOnly: False
  volumes:
  - name: hugepage
    emptyDir:
      medium: HugePages
```

- If your performance profile is not named `cnf-performance profile`, replace that string with the correct performance profile name.

### Huge pages resource injection for Downward API {#nw-sriov-hugepages_configuring-sriov-device}

When a pod specification includes a resource request or limit for huge pages, the Network Resources Injector automatically adds Downward API fields to the pod specification to provide the huge pages information to the container.

The Network Resources Injector adds a volume that is named `podnetinfo` and is mounted at `/etc/podnetinfo` for each container in the pod. The volume uses the Downward API and includes a file for huge pages requests and limits. The file naming convention is as follows:

- `/etc/podnetinfo/hugepages_1G_request_<container-name>`
- `/etc/podnetinfo/hugepages_1G_limit_<container-name>`
- `/etc/podnetinfo/hugepages_2M_request_<container-name>`
- `/etc/podnetinfo/hugepages_2M_limit_<container-name>`

The paths specified in the previous list are compatible with the `app-netutil` library. By default, the library is configured to search for resource information in the `/etc/podnetinfo` directory. If you choose to specify the Downward API path items yourself manually, the `app-netutil` library searches for the following paths in addition to the paths in the previous list.

- `/etc/podnetinfo/hugepages_request`
- `/etc/podnetinfo/hugepages_limit`
- `/etc/podnetinfo/hugepages_1G_request`
- `/etc/podnetinfo/hugepages_1G_limit`
- `/etc/podnetinfo/hugepages_2M_request`
- `/etc/podnetinfo/hugepages_2M_limit`

As with the paths that the Network Resources Injector can create, the paths in the preceding list can optionally end with a `_<container-name>` suffix.

## Configuring SR-IOV network devices {#nw-sriov-configuring-device_configuring-sriov-device}

The SR-IOV Network Operator adds the `SriovNetworkNodePolicy.sriovnetwork.openshift.io` custom resource definition (CRD) to OpenShift Container Platform. You can configure an SR-IOV network device by creating a `SriovNetworkNodePolicy` custom resource (CR).

> [!NOTE]
> When applying the configuration specified in a `SriovNetworkNodePolicy` CR, the SR-IOV Operator might drain the nodes, and in some cases, reboot nodes. Reboot only happens in the following cases:
>
> - With Mellanox NICs (`mlx5` driver) a node reboot happens every time the number of virtual functions (VFs) increase on a physical function (PF).
> - With Intel NICs, a reboot only happens if the kernel parameters do not include `intel_iommu=on` and `iommu=pt`.
>
> It might take several minutes for a configuration change to apply.

**Prerequisites**

- You installed the OpenShift CLI (`oc`).
- You have access to the cluster as a user with the `cluster-admin` role.
- You have installed the SR-IOV Network Operator.
- You have enough available nodes in your cluster to handle the evicted workload from drained nodes.
- You have not selected any control plane nodes for SR-IOV network device configuration.

**Procedure**

1. Create an `SriovNetworkNodePolicy` object, and then save the YAML in the `<name>-sriov-node-network.yaml` file. Replace `<name>` with the name for this configuration.
2. Optional: Label the SR-IOV capable cluster nodes with `SriovNetworkNodePolicy.Spec.NodeSelector` if they are not already labeled. For more information about labeling nodes, see "Understanding how to update labels on nodes".
3. Create the `SriovNetworkNodePolicy` object. When running the following command, replace `<name>` with the name for this configuration:

   ```terminal
   $ oc create -f <name>-sriov-node-network.yaml
   ```

   After applying the configuration update, all the pods in the `sriov-network-operator` namespace change to the `Running` status.
4. To verify your SR-IOV network device configuration, enter the following command and replace `<node_name>` with the name of the node where you configured the device.

   ```terminal
   $ oc get sriovnetworknodestates -n openshift-sriov-network-operator <node_name> -o jsonpath='{.status.syncStatus}'
   ```

**Additional resources**
{._additional-resources}

- [Understanding how to update labels on nodes](/openshift-docs-markdown/nodes/nodes/nodes-nodes-working#nodes-nodes-working-updating_nodes-nodes-working)

## Creating a non-uniform memory access (NUMA) aligned SR-IOV pod {#nw-sriov-topology-manager_configuring-sriov-device}

You can create a NUMA aligned SR-IOV pod by restricting SR-IOV and the CPU resources allocated from the same NUMA node with `restricted` or `single-numa-node` Topology Manager policies.

**Prerequisites**

- You have installed the OpenShift CLI (`oc`).
- You have configured the CPU Manager policy to `static`. For more information on CPU Manager, see the "Additional resources" section.
- You have configured the Topology Manager policy to `single-numa-node`.

  > [!NOTE]
  > When `single-numa-node` is unable to satisfy the request, you can configure the Topology Manager policy to `restricted`. For more flexible SR-IOV network resource scheduling, see *Excluding SR-IOV network topology during NUMA-aware scheduling* in the *Additional resources* section.

**Procedure**

1. Create the following SR-IOV pod spec, and then save the YAML in the `<name>-sriov-pod.yaml` file. Replace `<name>` with a name for this pod.

   The following example shows an SR-IOV pod spec:

   ```yaml
   apiVersion: v1
   kind: Pod
   metadata:
     name: sample-pod
     annotations:
       k8s.v1.cni.cncf.io/networks: <name>
   spec:
     containers:
     - name: sample-container
       image: <image>
       command: ["sleep", "infinity"]
       resources:
         limits:
           memory: "1Gi"
           cpu: "2"
         requests:
           memory: "1Gi"
           cpu: "2"
   ```

   - `<name>` specifies the name of the SR-IOV network attachment definition CR.
   - `<image>` specifies the name of the `sample-pod` image.
   - To create the SR-IOV pod with guaranteed QoS, set `memory limits` equal to `memory requests`.
   - To create the SR-IOV pod with guaranteed QoS, set `cpu limits` equal to `cpu requests`.
2. Create the sample SR-IOV pod by running the following command:

   ```terminal
   $ oc create -f <filename>
   ```

   - `<filename>` specifies the name of the file you created in the earlier step.
3. Confirm that the `sample-pod` is configured with guaranteed QoS.

   ```terminal
   $ oc describe pod sample-pod
   ```
4. Confirm that the `sample-pod` is allocated with exclusive CPUs.

   ```terminal
   $ oc exec sample-pod -- cat /sys/fs/cgroup/cpuset/cpuset.cpus
   ```
5. Confirm that the SR-IOV device and CPUs that are allocated for the `sample-pod` are on the same NUMA node.

   ```terminal
   $ oc exec sample-pod -- cat /sys/fs/cgroup/cpuset/cpuset.cpus
   ```

## Exclude the SR-IOV network topology for NUMA-aware scheduling {#nw-sriov-exclude-topology-manager_configuring-sriov-device}

You can exclude advertising the Non-Uniform Memory Access (NUMA) node for the SR-IOV network to the Topology Manager for more flexible SR-IOV network deployments during NUMA-aware pod scheduling.

In some scenarios, it is a priority to maximize CPU and memory resources for a pod on a single NUMA node. By not providing a hint to the Topology Manager about the NUMA node for the pod’s SR-IOV network resource, the Topology Manager can deploy the SR-IOV network resource and the pod CPU and memory resources to different NUMA nodes. This can add to network latency because of the data transfer between NUMA nodes. However, it is acceptable in scenarios when workloads require optimal CPU and memory performance.

For example, consider a compute node, `compute-1`, that features two NUMA nodes: `numa0` and `numa1`. The SR-IOV-enabled NIC is present on `numa0`. The CPUs available for pod scheduling are present on `numa1` only. By setting the `excludeTopology` specification to `true`, the Topology Manager can assign CPU and memory resources for the pod to `numa1` and can assign the SR-IOV network resource for the same pod to `numa0`. This is only possible when you set the `excludeTopology` specification to `true`. Otherwise, the Topology Manager attempts to place all resources on the same NUMA node.

## Troubleshooting SR-IOV configuration {#nw-sriov-troubleshooting_configuring-sriov-device}

After following the procedure to configure an SR-IOV network device, the following sections address some error conditions.

**Procedure**

- To display the state of nodes, run the following command:

  ```terminal
  $ oc get sriovnetworknodestates -n openshift-sriov-network-operator <node_name>
  ```

  `<node_name>` specifies the name of a node with an SR-IOV network device.

  If the output from the command indicates "cannot allocate memory", check the following items:

  - Confirm that global SR-IOV settings are enabled in the BIOS for the node.
  - Confirm that VT-d is enabled in the BIOS for the node.

**Additional resources**
{._additional-resources}

- [Using CPU Manager](/openshift-docs-markdown/scalability_and_performance/using-cpu-manager#using-cpu-manager)

**Additional resources**
{._additional-resources}

- [Configuring an SR-IOV network attachment](/openshift-docs-markdown/networking/hardware_networks/configuring-sriov-net-attach#configuring-sriov-net-attach)