title: Debugging low latency node tuning status
---

# Debugging low latency node tuning status {#cnf-debugging-low-latency-tuning-status}

Use the `PerformanceProfile` custom resource (CR) status fields for reporting tuning status and debugging latency issues in a cluster node.

## Debugging low latency CNF tuning status {#cnf-debugging-low-latency-cnf-tuning-status_cnf-debugging-low-latency}

To report tuning status and debug latency degradation issues, use the status fields in the `PerformanceProfile` custom resource (CR). These fields describe the conditions of the reconciliation functionality of an Operator, helping you verify the state of your configuration.

A typical issue can arise when the status of machine config pools that are attached to the performance profile are in a degraded state, causing the `PerformanceProfile` status to degrade. In this case, the machine config pool issues a failure message.

The Node Tuning Operator contains the `performanceProfile.spec.status.Conditions` status field:

```bash
Status:
  Conditions:
    Last Heartbeat Time:   2020-06-02T10:01:24Z
    Last Transition Time:  2020-06-02T10:01:24Z
    Status:                True
    Type:                  Available
    Last Heartbeat Time:   2020-06-02T10:01:24Z
    Last Transition Time:  2020-06-02T10:01:24Z
    Status:                True
    Type:                  Upgradeable
    Last Heartbeat Time:   2020-06-02T10:01:24Z
    Last Transition Time:  2020-06-02T10:01:24Z
    Status:                False
    Type:                  Progressing
    Last Heartbeat Time:   2020-06-02T10:01:24Z
    Last Transition Time:  2020-06-02T10:01:24Z
    Status:                False
    Type:                  Degraded
```

The `Status` field contains `Conditions` that specify `Type` values that indicate the status of the performance profile:

`Available`
:   All machine configs and Tuned profiles have been created successfully and are available for cluster components, such as NTO, MCO, Kubelet, that are responsible to process them.

`Upgradeable`
:   Indicates whether the resources maintained by the Operator are in a state that is safe to upgrade.

`Progressing`
:   Indicates that the deployment process from the performance profile has started.

`Degraded`
:   Indicates an error if:

    - Validation of the performance profile has failed.
    - Creation of all relevant components did not complete successfully.

Each of these types contain the following fields:

`Status`
:   The state for the specific type (`true` or `false`).

`Timestamp`
:   The transaction timestamp.

`Reason string`
:   The machine readable reason.

`Message string`
:   The human readable reason describing the state and error details, if any.

## Machine config pools {#cnf-debugging-low-latency-cnf-tuning-status-machineconfigpools_cnf-debugging-low-latency}

To apply performance profiles to specific nodes, associate them with a machine config pool (MCP). The MCP tracks the status of tuning updates, such as kernel arguments, huge pages, and real-time kernels, ensuring your cluster configurations are applied correctly.

The Performance Profile controller monitors changes in the MCP and updates the performance profile status accordingly.

The only conditions returned by the MCP to the performance profile status is when the MCP is `Degraded`, which leads to `performanceProfile.status.condition.Degraded = true`.

**Procedure**

1. Check the state of the associated machine config pool by entering the following command. The output example shows a performance profile with an associated machine config pool (`worker-cnf`) that is in a degraded state.

   ```terminal
   # oc get mcp
   ```

   ```terminal {title="Example output"}
   NAME         CONFIG                                                 UPDATED   UPDATING   DEGRADED   MACHINECOUNT   READYMACHINECOUNT   UPDATEDMACHINECOUNT   DEGRADEDMACHINECOUNT   AGE
   master       rendered-master-2ee57a93fa6c9181b546ca46e1571d2d       True      False      False      3              3                   3                     0                      2d21h
   worker       rendered-worker-d6b2bdc07d9f5a59a6b68950acf25e5f       True      False      False      2              2                   2                     0                      2d21h
   worker-cnf   rendered-worker-cnf-6c838641b8a08fff08dbd8b02fb63f7c   False     True       True       2              1                   1                     1                      2d20h
   ```
2. To check the reason for the degraded state, enter the following command, ensuring that you change the example machine config pool with your machine config pool. The `describe` section of the MCP shows the reason.

   ```terminal
   # oc describe mcp worker-cnf
   ```

   ```terminal {title="Example output"}
     Message:               Node node-worker-cnf is reporting: "prepping update:
     machineconfig.machineconfiguration.openshift.io \"rendered-worker-cnf-40b9996919c08e335f3ff230ce1d170\" not
     found"
       Reason:                1 nodes are reporting degraded status on sync
   ```
3. Optional: You can also run the `oc describe` command against the performance profile to check the degraded state status. The example output shows the performance profile `status` field marked as `degraded = true`:

   ```terminal
   # oc describe performanceprofiles performance
   ```

   ```terminal {title="Example output"}
   Message: Machine config pool worker-cnf Degraded Reason: 1 nodes are reporting degraded status on sync.
   Machine config pool worker-cnf Degraded Message: Node yquinn-q8s5v-w-b-z5lqn.c.openshift-gce-devel.internal is
   reporting: "prepping update: machineconfig.machineconfiguration.openshift.io
   \"rendered-worker-cnf-40b9996919c08e335f3ff230ce1d170\" not found".    Reason:  MCPDegraded
      Status:  True
      Type:    Degraded
   ```

## About the must-gather tool {#cnf-about-must-gather_cnf-debugging-low-latency}

To debug issues in your cluster, use the `oc adm must-gather` CLI command. This tool collects the diagnostic information most likely needed for troubleshooting, ensuring that you have the necessary data for analysis.

The `oc adm must-gather` CLI command collects the following information from your cluster:

- Resource definitions
- Audit logs
- Service logs

You can specify one or more images when you run the command by including the `--image` argument. When you specify an image, the tool collects data related to that feature or product. When you run `oc adm must-gather`, a new pod is created on the cluster. The data is collected on that pod and saved in a new directory that starts with `must-gather.local`. This directory is created in your current working directory.

## Collecting low latency tuning debugging data for Red Hat Support {#cnf-collecting-low-latency-tuning-debugging-data-for-red-hat-support_cnf-debugging-low-latency}

To debug low latency setup issues when opening a support case, collect diagnostic information for Red Hat Support using the `must-gather` tool. This command gathers essential data, such as node tuning and NUMA topology, from your OpenShift Container Platform cluster.

For prompt support, supply diagnostic information for both OpenShift Container Platform and low latency tuning.

Use the `oc adm must-gather` CLI command to collect the following information about your cluster, including features and objects associated with low latency tuning:

- The Node Tuning Operator namespaces and child objects.
- `MachineConfigPool` and associated `MachineConfig` objects.
- The Node Tuning Operator and associated Tuned objects.
- Linux kernel command-line options.
- CPU and NUMA topology
- Basic PCI device information and NUMA locality.

**Prerequisites**

- Access to the cluster as a user with the `cluster-admin` role.
- The OpenShift Container Platform OpenShift CLI (`oc`) installed.

**Procedure**

1. Navigate to the directory where you want to store the `must-gather` data.
2. Collect debugging information by running the following command:

   ```terminal
   $ oc adm must-gather
   ```

   ```terminal {title="Example output"}
   [must-gather      ] OUT Using must-gather plug-in image: quay.io/openshift-release
   When opening a support case, bugzilla, or issue please include the following summary data along with any other requested information:
   ClusterID: 829er0fa-1ad8-4e59-a46e-2644921b7eb6
   ClusterVersion: Stable at "<cluster_version>"
   ClusterOperators:
   	All healthy and stable

   [must-gather      ] OUT namespace/openshift-must-gather-8fh4x created
   [must-gather      ] OUT clusterrolebinding.rbac.authorization.k8s.io/must-gather-rhlgc created
   [must-gather-5564g] POD 2023-07-17T10:17:37.610340849Z Gathering data for ns/openshift-cluster-version...
   [must-gather-5564g] POD 2023-07-17T10:17:38.786591298Z Gathering data for ns/default...
   [must-gather-5564g] POD 2023-07-17T10:17:39.117418660Z Gathering data for ns/openshift...
   [must-gather-5564g] POD 2023-07-17T10:17:39.447592859Z Gathering data for ns/kube-system...
   [must-gather-5564g] POD 2023-07-17T10:17:39.803381143Z Gathering data for ns/openshift-etcd...

   ...

   Reprinting Cluster State:
   When opening a support case, bugzilla, or issue please include the following summary data along with any other requested information:
   ClusterID: 829er0fa-1ad8-4e59-a46e-2644921b7eb6
   ClusterVersion: Stable at "<cluster_version>"
   ClusterOperators:
   	All healthy and stable
   ```
3. Create a compressed file from the `must-gather` directory that was created in your working directory. For example, on a computer that uses a Linux operating system, run the following command:

   ```terminal
   $ tar cvaf must-gather.tar.gz must-gather-local.5421342344627712289//
   ```

   - `must-gather-local.5421342344627712289//`: Replace this value with the directory name created by the `must-gather` tool.

     > [!NOTE]
     > Create a compressed file to attach the data to a support case or to use with the Performance Profile Creator wrapper script when you create a performance profile.
4. Attach the compressed file to your support case on the [Red Hat Customer Portal](https://access.redhat.com/).

**Additional resources**
{._additional-resources}

- [Gathering data about your cluster with the `must-gather` tool](/openshift-docs-markdown/support/gathering-cluster-data#gathering-cluster-data)
- [Managing nodes with MachineConfig and KubeletConfig CRs](/openshift-docs-markdown/nodes/nodes/nodes-nodes-managing#nodes-nodes-managing)
- [Using the Node Tuning Operator](/openshift-docs-markdown/scalability_and_performance/using-node-tuning-operator#using-node-tuning-operator)
- [Configuring huge pages at boot time](/openshift-docs-markdown/scalability_and_performance/what-huge-pages-do-and-how-they-are-consumed-by-apps#configuring-huge-pages_huge-pages)
- [How huge pages are consumed by apps](/openshift-docs-markdown/scalability_and_performance/what-huge-pages-do-and-how-they-are-consumed-by-apps#how-huge-pages-are-consumed-by-apps_huge-pages)