title: Connecting a virtual machine to an SR-IOV network
---

# Connecting a virtual machine to an SR-IOV network {#virt-connecting-vm-to-sriov}

You can connect a virtual machine (VM) to the physical network by using a Single Root I/O Virtualization (SR-IOV) device.

To configure the SR-IOV network and attach the VM to that network, perform the following steps:

1. Configure an SR-IOV physical network device.
2. Define the secondary SR-IOV network.
3. Attach the VM to the SR-IOV network.

## Configuring SR-IOV network devices {#nw-sriov-configuring-device_virt-connecting-vm-to-sriov}

The SR-IOV Network Operator adds the `SriovNetworkNodePolicy.sriovnetwork.openshift.io` custom resource definition (CRD) to OpenShift Container Platform. You can configure an SR-IOV network device by creating a `SriovNetworkNodePolicy` custom resource (CR).

> [!NOTE]
> When applying the configuration specified in a `SriovNetworkNodePolicy` CR, the SR-IOV Operator might drain the nodes, and in some cases, reboot nodes. Reboot only happens in the following cases:
>
> - With Mellanox NICs (`mlx5` driver) a node reboot happens every time the number of virtual functions (VFs) increase on a physical function (PF).
> - With Intel NICs, a reboot only happens if the kernel parameters do not include `intel_iommu=on` and `iommu=pt`.
>
> It might take several minutes for a configuration change to apply.

**Prerequisites**

- You installed the OpenShift CLI (`oc`).
- You have access to the cluster as a user with the `cluster-admin` role.
- You have installed the SR-IOV Network Operator.
- You have enough available nodes in your cluster to handle the evicted workload from drained nodes.
- You have not selected any control plane nodes for SR-IOV network device configuration.

**Procedure**

1. Create an `SriovNetworkNodePolicy` object, and then save the YAML in the `<name>-sriov-node-network.yaml` file. Replace `<name>` with the name for this configuration.

   ```yaml
   apiVersion: sriovnetwork.openshift.io/v1
   kind: SriovNetworkNodePolicy
   metadata:
     name: <name>
     namespace: openshift-sriov-network-operator
   spec:
     resourceName: <sriov_resource_name>
     nodeSelector:
       feature.node.kubernetes.io/network-sriov.capable: "true"
     priority: <priority>
     mtu: <mtu>
     numVfs: <num>
     nicSelector:
       vendor: "<vendor_code>"
       deviceID: "<device_id>"
       pfNames: ["<pf_name>", ...]
       rootDevices: ["<pci_bus_id>", "..."]
     deviceType: vfio-pci
     isRdma: false
   ```

   - `metadata.name` defines a name for the `SriovNetworkNodePolicy` object.
   - `metadata.namespace` defines the namespace where the SR-IOV Network Operator is installed.
   - `spec.resourceName` defines the resource name of the SR-IOV device plugin. You can create multiple `SriovNetworkNodePolicy` objects for a resource name.
   - `spec.nodeSelector.feature.node.kubernetes.io/network-sriov.capable` defines the node selector to select which nodes are configured. Only SR-IOV network devices on selected nodes are configured. The SR-IOV Container Network Interface (CNI) plugin and device plugin are deployed only on selected nodes.
   - `spec.priority` is an optional field that defines an integer value between `0` and `99`. A smaller number gets higher priority, so a priority of `10` is higher than a priority of `99`. The default value is `99`.
   - `spec.mtu` is an optional field that defines a value for the maximum transmission unit (MTU) of the virtual function. The maximum MTU value can vary for different NIC models.
   - `spec.numVfs` defines the number of the virtual functions (VF) to create for the SR-IOV physical network device. For an Intel network interface controller (NIC), the number of VFs cannot be larger than the total VFs supported by the device. For a Mellanox NIC, the number of VFs cannot be larger than `127`.
   - `spec.nicSelector` defines the Ethernet device for the Operator to configure. You do not need to specify values for all the parameters.

     > [!NOTE]
     > It is recommended to identify the Ethernet adapter with enough precision to minimize the possibility of selecting an Ethernet device unintentionally. If you specify `rootDevices`, you must also specify a value for `vendor`, `deviceID`, or `pfNames`.

     If you specify both `pfNames` and `rootDevices` at the same time, ensure that they point to an identical device.
   - `spec.nicSelector.vendor` is an optional field that defines the vendor hex code of the SR-IOV network device. The only allowed values are either `8086` or `15b3`.
   - `spec.nicSelector.deviceID` is an optional field that defines the device hex code of SR-IOV network device. The only allowed values are `158b`, `1015`, `1017`.
   - `spec.nicSelector.pfNames` is an optional field that defines an array of one or more physical function (PF) names for the Ethernet device.
   - `spec.nicSelector.rootDevices` is an optional field that defines an array of one or more PCI bus addresses for the physical function of the Ethernet device. Provide the address in the following format: `0000:02:00.1`.
   - `spec.deviceType` defines the driver type. The `vfio-pci` driver type is required for virtual functions in OpenShift Virtualization.
   - `spec.isRdma` is an optional field that defines whether to enable remote direct memory access (RDMA) mode. For a Mellanox card, set `isRdma` to `false`. The default value is `false`.

     > [!NOTE]
     > If `isRDMA` flag is set to `true`, you can continue to use the RDMA enabled VF as a normal network device. A device can be used in either mode.
2. Optional: Label the SR-IOV capable cluster nodes with `SriovNetworkNodePolicy.Spec.NodeSelector` if they are not already labeled. For more information about labeling nodes, see "Understanding how to update labels on nodes".
3. Create the `SriovNetworkNodePolicy` object. When running the following command, replace `<name>` with the name for this configuration:

   ```terminal
   $ oc create -f <name>-sriov-node-network.yaml
   ```

   After applying the configuration update, all the pods in the `sriov-network-operator` namespace change to the `Running` status.
4. To verify your SR-IOV network device configuration, enter the following command and replace `<node_name>` with the name of the node where you configured the device.

   ```terminal
   $ oc get sriovnetworknodestates -n openshift-sriov-network-operator <node_name> -o jsonpath='{.status.syncStatus}'
   ```

## Configuring SR-IOV additional network {#nw-sriov-additional-network_virt-connecting-vm-to-sriov}

You can configure an additional network that uses SR-IOV hardware by creating an `SriovNetwork` object. When you create an `SriovNetwork` object, the SR-IOV Network Operator automatically creates a `NetworkAttachmentDefinition` object.

> [!NOTE]
> Do not modify or delete an `SriovNetwork` object if it is attached to pods or virtual machines in a `running` state.

**Prerequisites**

- Install the OpenShift CLI (`oc`).
- Log in as a user with `cluster-admin` privileges.

**Procedure**

1. Create the following `SriovNetwork` object, and then save the YAML in the `<name>-sriov-network.yaml` file. Replace `<name>` with a name for this additional network.

   ```yaml
   apiVersion: sriovnetwork.openshift.io/v1
   kind: SriovNetwork
   metadata:
     name: <name>
     namespace: openshift-sriov-network-operator
   spec:
     resourceName: <sriov_resource_name>
     networkNamespace: <target_namespace>
     vlan: <vlan>
     spoofChk: "<spoof_check>"
     linkState: <link_state>
     maxTxRate: <max_tx_rate>
     minTxRate: <min_rx_rate>
     vlanQoS: <vlan_qos>
     trust: "<trust_vf>"
     capabilities: <capabilities>
   ```

   - `metadata.name` defines a name for the `SriovNetwork` object. The SR-IOV Network Operator creates a `NetworkAttachmentDefinition` object with same name.
   - `metadata.namespace` defines the namespace where the SR-IOV Network Operator is installed.
   - `spec.resourceName` defines the value of the `.spec.resourceName` parameter in the `SriovNetworkNodePolicy` object that defines the SR-IOV hardware for this additional network.
   - `spec.networkNamespace` defines the target namespace for the `SriovNetwork` object. Only pods or virtual machines in the target namespace can attach to the `SriovNetwork` object.
   - `spec.vlan` an optional field that defines a Virtual LAN (VLAN) ID for the additional network. The integer value must be from `0` to `4095`. The default value is `0`.
   - `spec.spoofChk` an optional field that defines the spoof check mode of the VF. The allowed values are the strings `"on"` and `"off"`.

     > [!IMPORTANT]
     > You must enclose the value you specify in quotes or the CR is rejected by the SR-IOV Network Operator.
   - `spec.linkState` an optional field that defines the link state of virtual function (VF). Allowed values are `enable`, `disable` and `auto`.
   - `spec.maxTxRate` an optional field that defines the maximum transmission rate, in Mbps, for the VF.
   - `spec.minTxRate` an optional field that defines the minimum transmission rate, in Mbps, for the VF. This value should always be less than or equal to the maximum transmission rate.

     > [!NOTE]
     > Intel NICs do not support the `minTxRate` parameter. For more information, see [BZ#1772847](https://bugzilla.redhat.com/show_bug.cgi?id=1772847).
   - `spec.vlanQoS` an optional field that defines the IEEE 802.1p priority level for the VF. The default value is `0`.
   - `spec.trust` an optional field that defines the trust mode of the VF. The allowed values are the strings `"on"` and `"off"`.

     > [!IMPORTANT]
     > You must enclose the value you specify in quotes or the CR is rejected by the SR-IOV Network Operator.
   - `spec.capabilities` an optional field that defines the capabilities to configure for this network.
2. To create the object, enter the following command. Replace `<name>` with a name for this additional network.

   ```terminal
   $ oc create -f <name>-sriov-network.yaml
   ```
3. Optional: To confirm that the `NetworkAttachmentDefinition` object associated with the `SriovNetwork` object that you created in the previous step exists, enter the following command. Replace `<namespace>` with the namespace you specified in the `SriovNetwork` object.

   ```terminal
   $ oc get net-attach-def -n <namespace>
   ```

## Connecting a virtual machine to an SR-IOV network by using the CLI {#virt-attaching-vm-to-sriov-network_virt-connecting-vm-to-sriov}

You can connect the virtual machine (VM) to the SR-IOV network by including the network details in the VM configuration.

**Prerequisites**

- You have installed the OpenShift CLI (`oc`).

**Procedure**

1. Add the SR-IOV network details to the `spec.domain.devices.interfaces` and `spec.networks` stanzas of the VM configuration as in the following example:

   ```yaml
   apiVersion: kubevirt.io/v1
   kind: VirtualMachine
   metadata:
     name: example-vm
   spec:
     domain:
       devices:
         interfaces:
         - name: nic1
           sriov: {}
     networks:
     - name: nic1
       multus:
           networkName: sriov-network
   # ...
   ```

   - `spec.template.spec.domain.devices.interfaces.name` specifies a unique name for the SR-IOV interface.
   - `spec.template.spec.networks.name` specifies the name of the SR-IOV interface. This must be the same as the `interfaces.name` that you defined earlier.
   - `spec.template.spec.networks.multus.networkName` specifies the name of the SR-IOV network attachment definition.
2. Apply the virtual machine configuration:

   ```terminal
   $ oc apply -f <vm_sriov>.yaml
   ```

   where:

   `<vm_sriov>`
   :   Specifies the name of the virtual machine YAML file.

## Connecting a VM to an SR-IOV network by using the web console {#virt-attaching-vm-to-sriov-network-web-console_virt-connecting-vm-to-sriov}

You can connect a VM to the SR-IOV network by including the network details in the VM configuration.

**Prerequisites**

- You must create a network attachment definition for the network.

**Procedure**

1. Navigate to **Virtualization** → **VirtualMachines**.
2. Click a VM to view the **VirtualMachine details** page.
3. On the **Configuration** tab, click the **Network interfaces** tab.
4. Click **Add network interface**.
5. Enter the interface name.
6. Select an SR-IOV network attachment definition from the **Network** list.
7. Select `SR-IOV` from the **Type** list.
8. Optional: Add a network **Model** or **Mac address**.
9. Click **Save**.
10. Restart or live-migrate the VM to apply the changes.

**Additional resources**
{._additional-resources}